Use #4 or #6 screws to mount the sensor in place
Optional External Contact
•
Optional External contact wiring.
•
Optional external contact zone is: normally closed – alarm on open.
•
No end-of-line resistors on external contact.
Note:
External contact not evaluated by ETL
Operation
•
Motion sends wireless transmission after 2 or 3 pulses.
•
Normal sensitivity (default): 3 pulses
•
High sensitivity: 2 pulses
•
Sensitivity set by the internal jumper block.
•
Motion stops (locks out) transmitting wireless sensor alarms for 3 minutes after
sending an alarm transmission.
This is to conserve battery life.
•
Tamper, when cover is opened.
•
Supervisory signal sent every hour
•
LED Walk Test: Press Tamper for 3 minute test:
•
LED lights when motion sensed
•
Sensor re-calibrates for 10 to 30 seconds after each LED blink.
It will not transmit during re-calibration.
So wait about 30 seconds before first test, and 30 seconds between tests.
•
Wireless transmissions sent for each detection, so walk test can be used for
panel operation test as well
Ceiling
Floor
Wall
Optional external contact terminals
Ceiling
Specifications
Specifications subject to change without notice.
Use this model for ALL pet situations.
RE020 Horizontal Beam Lens also available for unique situations.
Notices
Warranty
Resolution Products, Inc. will replace products that are defective in their first five (5) years.
FCC Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by the Resolution Products, Inc. could void
the user's authority to operate this equipment.
FCC ID: U5X-RE310
IC Notice
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
(1)This device may not cause interference, and
(2)This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1)l'appareil ne doit pas produire de brouillage, et
(2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
IC: 8310A-RE310
Manual: 47-0005-08 Rev A
Wall
For further information visit us:
@
www.connect-o2.com.au |
02 9749 5888 | [email protected]