background image

Use #4 or #6 screws to mount the sensor in place

Optional External Contact 

Optional External contact wiring.

Optional external contact zone is: normally closed – alarm on open.

No end-of-line resistors on external contact.

Note: 

External contact not evaluated by ETL

 

Operation 

Motion sends wireless transmission after 2 or 3 pulses.

Normal sensitivity (default): 3 pulses

High sensitivity: 2 pulses

Sensitivity set by the internal jumper block.

Motion stops (locks out) transmitting wireless sensor alarms for 3 minutes after
sending an alarm transmission.

  This is to conserve battery life.

Tamper, when cover is opened.

Supervisory signal sent every hour

LED Walk Test:   Press Tamper for 3 minute test:

LED lights when motion sensed

Sensor re-calibrates for 10 to 30 seconds after each LED blink.
It will not transmit during re-calibration.
So wait about 30 seconds before first test, and 30 seconds between tests.

Wireless transmissions sent for each detection, so walk test can be used for
panel operation test as well

Ceiling

Floor

Wall

Optional external contact terminals 

Ceiling

Specifications 

Specifications subject to change without notice. 
Use this model for ALL pet situations.   
RE020 Horizontal Beam Lens also available for unique situations.

 

Notices 

Warranty 
Resolution Products, Inc. will replace products that are defective in their first five (5) years. 

FCC Notice 

This device complies with Part 15 of the FCC rules.  Operation is subject to the following two 
conditions: 

This device may not cause harmful interference. 
This device must accept any interference that may be received, including interference 
that may cause undesired operation. 

Changes or modifications not expressly approved by the Resolution Products, Inc. could void 
the user's authority to operate this equipment. 

FCC ID: U5X-RE310 

IC Notice 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is 
subject to the following two conditions: 

(1)This device may not cause interference, and 
(2)This device must accept any interference, including interference that may 

 cause undesired operation of the device. 

Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils 
radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : 

(1)l'appareil ne doit pas produire de brouillage, et 
(2)l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, 
même si le brouillage est susceptible d'en compromettre le fonctionnement. 

IC: 8310A-RE310 

Manual: 47-0005-08 Rev A 

Wall

 

For further information visit us:

@ 

www.connect-o2.com.au  |  

  

02 9749 5888    |  [email protected]

  