Scope of delivery:

1 x pump station 

FlowSol

®

 

C

1 x flushing and filling unit (optional)
1 x wall mounting bracket

About this product

The pump station 

FlowSol

®

 

C

 is a preinstalled and 

leak-tested group of fittings for transferring heat from 
the collector to the store. It contains important fit-
tings and safety devices for the operation of the solar 
thermal system:

• 

Ball valves in flow and return in combination with 
check valves to prevent gravity circulation

• 

Air separator for manual bleeding of the solar 
thermal system

• 

Flowmeter for displaying the flow rate

• 

Manometer for displaying the system pressure

• 

Safety valve to prevent inadmissible overpressure

• 

Flushing and filling unit (optional) for flushing, filling 
and emptying the solar thermal system

Overview

• 

Integrated controller 

DeltaSol

®

 C

• 

Outstanding design

• 

Safety assembly with safety valve and  
pressure gauge

• 

High-quality casing for reduced heat losses

• 

Flowmeter

Technical data 
Dimensions (H x W x D):

approx. 417 x 374 x 179 mm (incl. insulation)

Distance centre: 1600 mm 
Distance axis / wall: 55 mm

Pipe connections: 

¾" IT

Connection to diaphragm-type expansion  
vessel:

 ¾" ET, flat sealing

Outlet safety valve:

 ¾" IT

Safety valve: 

6 bar

Pressure gauge: 

0 ... 6 bar

Non-return valve: 

Opening pressure 20 mbar, 

openable

Max. permitted pressure: 

6 bar

Admissible max. temperature:

 +120 °C

Material:

Fittings: brass 
Seals: EPDM 
Insulation: EPP, 

l

 = 0,041 W/(m*K)

Flowmeter:

 1 ... 20 l/min

160 mm

55 mm

Summary of Contents for FlowSol C

Page 1: ...on Operation Commissioning Manual for the specialised craftsman Thank you for buying this RESOL product Please read this manual carefully to get the best performance from this unit Please keep this ma...

Page 2: ...rks Initial installation must be effected by qualified per sonnel named by the manufacturer Description of symbols WARNING Warnings are indicated with a warn ing triangle They contain information on h...

Page 3: ...ressure Safety valve to prevent inadmissible overpressure Flushing and filling unit optional for flushing filling and emptying the solar thermal system 1 Overview Integrated controller DeltaSol C Outs...

Page 4: ...lushing and filling the solar thermal system Attention Risk of scalding To prevent the solar fluid boiling in the collectors the system should not be flushed or filled during periods of strong sunshin...

Page 5: ...al times at the Air separator until the dischar ged solar fluid is free of air bubbles Close the drain ball valve 3 of the flushing and fil ling unit with the filling pump running and increase the sys...

Page 6: ...ector circuit the flow rate in the flow must be at least 0 3 m s Check the system pressure after bleeding and if ne cessary increase it to the specified operating pressure WARNING Risk of injury cause...

Page 7: ...7 en Notes...

Page 8: ...e completeness of the drawings and texts of this manual they only represent some examples They can only be used at your own risk No liability is assumed for incorrect incomplete or false information a...

Reviews: