The controller compares the temperature at the sensor of
the solid fuel boiler or boiler inserted in stove (S1) with
the temperature at the sensor at store (S2). If the detec-
ted temperature difference is higher than or equals the
preadjusted value
∆
T, the pump (RO) is switched-on when
simultaneously the given minimum temperature is reached
or exceeded. The temperature difference is reduced.
Store charge
1
S1
S2
2 3
4
7
RO RC N N L
8 9 10 11
S1
R0
S2
ON
OFF
1
2
3
4
C
ON
OFF
1
2
3
4
A
ON
OFF
1
2
3
4
B
If the difference 1,6 K (hysterisis, can difference is reduced,
cannot be changed) underruns the adjusted temperature
difference, the pump is switched-off again.
S1 = boiler sensor
S2 = store sensor
RO = circulation pump