3.7 

Minimum temperature limitation

With DIP switch 4, the temperature limitation can be 
activated as a minimum temperature limitation. The 
limit temperature can be adjusted by means of the 
potentiometer C. The sensor connected to the termi-
nals S1 is used as the reference sensor. The minimum 
collector temperature is the minimum switch-on tem-
perature which must be exceeded for the solar pump 
(R1) to switch on.

C

ON

OFF

1

2

3

4

E

ON

OFF

1

2

3

4

A

Examples

4.1 

Standard solar system with 1 store

7

RO RC N N L

8 9 10 11

2

2

2

3

3

S1

RO

S2

 Use grounding terminals!

The controller calculates the temperature difference 
between collector sensor S1 and store sensor S2. If 
the difference is larger than or identical to the adjust-
ed switch-on temperature difference, the pump (R1) 
will be switched on and the store will be loaded. If the 
temperature difference falls by 1.6 K (non-adjustable 
hysteresis) below the adjusted temperature difference, 
the pump will be switched off.

S1  =  Collector sensor
S2  =  Store sensor
RO  =  Solar pump

ON

OFF

1

2

3

4

C

Deactivated by default (DIP 
switch in OFF position), de-
fault setting upon activation: 
60 °C

3.8 

Minimum speed (speed control via PWM signal)

With potentiometre D, a relative minimum speed can 
be adjusted for a HE pump connected to the relay. If 
the temperature difference reaches or exceeds the 
switch-on temperature difference, the pump switches 
on at 100 % speed for 10 s. Then, the speed is reduced 
to the minimum pump speed value. If the temperature 
difference reaches the adjusted nominal value, the 
pump speed increases by one step (10 %).

By means of the three-pole jumper on the left-hand side above the output termi-
nals, the PWM profile for the HE pump can be selected.
Jumper position left: Output signal not inverted (solar pump)
Jumper position right: Output signal inverted (heating pump)

3.9 

PWM profile

S

H

Adjustment range: 
20 … 100 %
Factory setting: 30 %

D

Mains

Input 
100 %

Heating

Solar

PWM / 0-10 V 
output

100%

0%

ON

OFF

1

2

3

4

A

ON

OFF

1

2

3

4

ON

OFF

1

2

3

4

Summary of Contents for DeltaSol AX HE

Page 1: ...d this manual carefully to get the best performance from this unit Please keep this manual safe DeltaSol AX HE www resol com Manual en Differential temperature controller Manual for the specialised cr...

Page 2: ...exclusively addressed to authorised skilled personnel Only qualified electricians should carry out electrical works Initial installation must be effected by the system owner or qualified personnel nam...

Page 3: ...ntees a protection against dripping water 1 Overview 4 2 Installation 4 2 1 Mounting 4 2 2 Electrical connection 6 3 Operation and function 6 3 1 Flashing codes 6 3 2 DIP switches and potentiometres 6...

Page 4: ...m temperature limitation Housing plastic PC ABS and PMMA Mounting wall mounting Indication Display 1 operating control LED Operation 3 potentiometres 4 DIP switches 1 jumper Protection type IP 20 DIN...

Page 5: ...2 2 1 112mm 2 5 6 7 3 8 4 T4A fuse Mains connection Relay load Grounding terminal common terminal block Sensor 1 2 PWM output DIP switches Switch on temperature difference potentiometre Temperature li...

Page 6: ...normally closed contact 9 neutral conductor N Grounding terminal common terminal block Speed control of a HE pump is possible via a PWM signal The pump has to be connected to the relay power supply as...

Page 7: ...the manual mode is active the operating control lamp flashes red and green 3 4 Manual mode 3 5 Maximum temperature limitation With DIP switch 2 the temperature limitation can be activated as a maximum...

Page 8: ...eresis below the adjusted temperature difference the pump will be switched off S1 Collector sensor S2 Store sensor RO Solar pump ON OFF 1 2 3 4 C Deactivated by default DIP switch in OFF position de f...

Page 9: ...cuit return preheating Use grounding terminals The controller calculates the temperature difference between collector sensor S1 and store sensor S2 If the difference is larger than or identical to the...

Page 10: ...nce falls by 1 6K non adjust able hysteresis below the adjusted temperature differ ence the pump will be switched off S1 Solid fuel boiler sensor S2 Store sensor RO Circulating pump 5 Accessories SP10...

Page 11: ...nnected temperature sensors can be checked with an ohmmeter Please check if the resistance values correspond with the table C F Pt1000 C F Pt1000 10 14 961 55 131 1213 5 23 980 60 140 1232 0 32 1000 6...

Page 12: ...r the completeness of the drawings and texts of this manual they only represent some examples They can only be used at your own risk No liability is assumed for incorrect incomplete or false informati...

Reviews: