Safety advice

Please pay attention to the following safety advice in order to avoid danger and 
damage to people and property.

Instructions

Attention must be paid to the valid local standards, regulations and directives!

Information about the product
Proper usage

The differential temperature controller is designed for electronically controlling 
solar thermal, heating and air conditioning systems in compliance with the technical 
data specified in this manual.
Improper use excludes all liability claims.
CE Declaration of conformity

The product complies with the relevant directives and is therefore 
labelled with the CE mark. The Declaration of Conformity is available 
upon request, please contact the manufacturer.

Note
Strong electromagnetic fields can impair the function of the device.

 

Î

Make sure the device as well as the system are not exposed to strong 
electromagnetic fields.

Target group

These instructions are exclusively addressed to authorised skilled personnel.
Only qualified electricians should carry out electrical works.
Initial installation must be effected by the system owner or qualified personnel 
named by the system owner.

Description of symbols

WARNING!

Warnings are indicated with a warning triangle!

 

Î

They contain information on how to avoid the danger 
described.

Signal words describe the danger that may occur, when it is not avoided.
•  WARNING means that injury, possibly life-threatening injury, can occur.
•  ATTENTION means that damage to the appliance can occur.

Note
Notes are indicated with an information symbol.

Cross reference
A book symbol indicates a cross reference to another chapter.

 

Î

Arrows indicate instruction steps that should be carried out.

Disposal

•  Dispose of the packaging in an environmentally sound manner.
•  At the end of its working life, the product must not be disposed of as urban waste. 

Old appliances must be disposed of by an authorised body in an environmentally 
sound manner. Upon request we will take back your old appliances bought from 
us and guarantee an environmentally sound disposal of the devices.

Subject to technical change. Errors excepted.

Summary of Contents for DeltaSol AX HE

Page 1: ...d this manual carefully to get the best performance from this unit Please keep this manual safe DeltaSol AX HE www resol com Manual en Differential temperature controller Manual for the specialised cr...

Page 2: ...exclusively addressed to authorised skilled personnel Only qualified electricians should carry out electrical works Initial installation must be effected by the system owner or qualified personnel nam...

Page 3: ...ntees a protection against dripping water 1 Overview 4 2 Installation 4 2 1 Mounting 4 2 2 Electrical connection 6 3 Operation and function 6 3 1 Flashing codes 6 3 2 DIP switches and potentiometres 6...

Page 4: ...m temperature limitation Housing plastic PC ABS and PMMA Mounting wall mounting Indication Display 1 operating control LED Operation 3 potentiometres 4 DIP switches 1 jumper Protection type IP 20 DIN...

Page 5: ...2 2 1 112mm 2 5 6 7 3 8 4 T4A fuse Mains connection Relay load Grounding terminal common terminal block Sensor 1 2 PWM output DIP switches Switch on temperature difference potentiometre Temperature li...

Page 6: ...normally closed contact 9 neutral conductor N Grounding terminal common terminal block Speed control of a HE pump is possible via a PWM signal The pump has to be connected to the relay power supply as...

Page 7: ...the manual mode is active the operating control lamp flashes red and green 3 4 Manual mode 3 5 Maximum temperature limitation With DIP switch 2 the temperature limitation can be activated as a maximum...

Page 8: ...eresis below the adjusted temperature difference the pump will be switched off S1 Collector sensor S2 Store sensor RO Solar pump ON OFF 1 2 3 4 C Deactivated by default DIP switch in OFF position de f...

Page 9: ...cuit return preheating Use grounding terminals The controller calculates the temperature difference between collector sensor S1 and store sensor S2 If the difference is larger than or identical to the...

Page 10: ...nce falls by 1 6K non adjust able hysteresis below the adjusted temperature differ ence the pump will be switched off S1 Solid fuel boiler sensor S2 Store sensor RO Circulating pump 5 Accessories SP10...

Page 11: ...nnected temperature sensors can be checked with an ohmmeter Please check if the resistance values correspond with the table C F Pt1000 C F Pt1000 10 14 961 55 131 1213 5 23 980 60 140 1232 0 32 1000 6...

Page 12: ...r the completeness of the drawings and texts of this manual they only represent some examples They can only be used at your own risk No liability is assumed for incorrect incomplete or false informati...

Reviews: