Resol DeltaSol AL Installation Instructions Manual Download Page 5

DeltaSol

®

 

AL

|

© RESOL 10341 deltasol_al.mon

us.ind

d

The controller is equipped with the RESOL VBus

®

 

for data 

transfer with and energy supply to external modules. Carry 
out the connection at the two terminals marked “VBus” (any 
polarity). One or more RESOL VBus

®

 modules can be con-

nected via this data bus, such as: 

 

• RESOL GA3 Large Display from version 1.21

 

• RESOL SD3 Smart Display from version 1.21

 

• RESOL DL2 Datalogger

 

• RESOL VBus

®

 / USB interface adapter

Connecting the device to the power supply must always be 

the last step of the installation!
The controller is supplied with power via a power supply 
line. The power supply of the device must be 100 ... 240 V~ 

(50 ... 60 Hz) . 
The controller is equipped with a change-over relay to which 

load

 such as a pump, a valve, etc. can be connected:

10  =  ground terminal 

 

11  =  ground terminal 

 

12  =  conductor R1-R (normally closed contact) 
13  =  conductor R1-A (normally open contact) 
14  =  neutral conductor N
Depending on the product version, power supply cable and 

sensor cables are already connected to the device. If that is 

not the case, please proceed as follows:
Connect the 

temperature sensors 

(S1 to S3) to the 

corres ponding terminals with either polarity:
1/2  =  Sensor 1 (e. g. sensor collector)
3/4  =  Sensor 2 (e. g. sensor tank)
5/6  =  Sensor 3 (e. g. sensor tank top)
Connect the RESOL VBus

®

 

to the terminals marked 

“VBus” with either polarity:
7  =  VBus terminal
8  =  VBus terminal
Connect the 

power supply cable

 to the following ter-

minals:
15  =  neutral conductor N

16  =  conductor L
9  =  ground terminal 

 

Attach flexible cables to the housing with the enclosed 

strain relief and the corresponding screws.

aTTEnTiOn! ESD damage!

Electrostatic discharge can cause dam-
age of electronic components!

 

Î

Ta k e   c a r e   t o   d i s c h a r g e 
proper ly before touching the 
inside of the device!

2.2 

Electrical connection

2.3 

Data communication / Bus

Summary of Contents for DeltaSol AL

Page 1: ...L product Please read this manual carefully to get the best performance from this unit Please keep this manual carefully RESOL DeltaSol AL Mounting Connection Operation Troubleshooting Examples Manual...

Page 2: ...contents Advice 2 1 Overview 3 2 Installation 4 2 1 Mounting 4 2 2 Electrical connection 5 2 3 Data communication Bus 5 2 4 Terminal allocation 6 3 Operation 6 3 1 Buttons for adjustment 6 3 2 System...

Page 3: ...tem states background illumination and operating control lamp Operation 3 push buttons at the front of the housing and 1 slide switch Functions Differential temperature controller for standard solar t...

Page 4: ...ver Mark the upper fastening point on the wall Drill and fasten the enclosed wall plug and screw leaving the head protruding Hang the housing from the upper fastening point and mark the lower fastenin...

Page 5: ...erminal 12 conductor R1 R normally closed contact 13 conductor R1 A normally open contact 14 neutral conductor N Depending on the product version power supply cable and sensor cables are already conne...

Page 6: ...ards through the display menu or to increase the adjustment values Button 2 is similarly used for scrolling forward and reducing values In order to access the adjustment mode scroll down in the displa...

Page 7: ...e indication is set to F and Ra the units are not displayed 3 2 1 Channel display Channel display 3 2 2 Tool bar The additional symbols in the tool bar indicate the current system state Tool bar 3 2 S...

Page 8: ...ing OK red green flashing initialization phase manual operation red flashing Sensor defective sensor symbol is flashing quickly 3 4 Flashing codes 3 4 2 LED flashing codes 3 4 1 System Screen flashing...

Page 9: ...mperature TST tank temperature TST tank temperature display range 40 260 C 40 500 F Display sensor 3 Shows the current temperature of the additional sensor without control function S3 temperature sens...

Page 10: ...n are used for determining the heat quantity delivered It is shown in kWh in the channel kWh and in MWh in the channel MWh The overall heat quantity results from the sum of both values The accumulated...

Page 11: ...Ra Collector temperature limitation for emergency shutdown of the collector If the adjusted collector emergency shutdown temperature EM is exceeded the controller switches off the solar pump in order...

Page 12: ...cuit will be deactivated Option recooling If the adjusted maximum tank temperature S MX is reached the controller keeps the solar pump running in order to prevent the collector from being overheated T...

Page 13: ...In this adjustment channel the menu language can be chosen dE German En English It Italian Fr French LANG language selection adjustment range dE En It Fr factory setting En Temperature units In this...

Page 14: ...resistance values corresponding to different temperatures are listed yes Check the supply line and reconnect it If a malfunction occurs an error code will be indicated on the display by means of symb...

Page 15: ...Heat exchanger blocked yes no Clean it Heat exchanger too small yes Replace with correctly sized one no Plausibility control of the tube collector function Change Ton and Toff correspondingly Switch o...

Page 16: ...Does the pump start up in manual operation yes No current check fuses replace them and check power supply The adjusted temperature difference for starting the pump is to high choose a value which make...

Page 17: ...the data issued by the controller collector and tank temperature as well as heat quantity produced in the solar system The use of high efficient LEDs and antireflective filter glass assures a high opt...

Page 18: ...DeltaSol AL 18 RESOL 10341 deltasol_al monus indd Notes...

Page 19: ...DeltaSol AL 19 RESOL 10341 deltasol_al monus indd Notes...

Page 20: ...f RESOL Elektronische Regelungen GmbH This especially applies for copies translations micro films and the storage into electronic systems Editor RESOL Elektronische Regelungen GmbH Important notice Th...