background image

6

  English    7

Technical specifications

Battery technology

Lithium ion

Capacity

< 100 Wh (97 Wh)

UN classification

UN3481 (lithium-ion batteries packed with equipment)

AC power supply

Input range 100–240V, 50–60Hz, 1.0-1.5A

Nominal for aircraft use 110V, 400Hz 

DC converter

Input range 12V / 24V, 13A / 6.5A

Battery output voltage

(24V / 26V) ± 0.5V, 90W continuous

Power supply unit output 

current (rated)

3.75 A 

Battery output current (rated)

3.75 A / 3.46 A

Standby current

< 100 μA

Protection

Overcharge, overdischarge, excess current, short circuit, 

high temperature

Dimensions (L x W x H)

9.1” x 5.0” x 1.0” (230 mm x 126 mm x 26 mm)

Battery weight

2.0 lb (0.9 kg)

System weight

5.1 lb (2.3 kg)

Minimum life cycle

≥ 500 cycles at 73°F (23°C) to 60% capacity

Operating conditions

Charging

Discharging

 

41°F to +104°F (5°C to 40°C); 5–85% maximum humidity

23°F to +104°F (-5°C to 40°C); 5–85% maximum humidity

Transport/storage conditions

-4°F to +113°F (-20°C to +45°C); 5–85% maximum 

humidity

Operating/storage air pressure

600 hPa to 1100 hPa

Aircraft use

Product meets the Federal Aviation Administration (FAA) 

requirements (RTCA/D0-160, section 21, category M) for 

all phases of air travel.

Recharge time

< 4 hrs at full level

Electromagnetic compatibility

Product complies with all applicable electromagnetic 

compatibility requirements (EMC) according to IEC60601-

1-2, for residential, commercial, and light industry 

environments. Information regarding the electromagnetic 

emissions and immunity of these ResMed devices can 

be found on www.resmed.com, on the Products page 

under Service and Support. Click on the PDF file for your 

language.

IEC 60601-1 classification

Class II (double insulation) and/or Internally Powered 

Equipment, IP21 (IP20 while charging), Continuous 

Operation (from mains), Limited Operation (from 

battery), Equipment not suitable for use in the presence 

of a flammable anaesthetic mixture with air or with 

oxygen or nitrous oxide.

Battery run time

> 8 hrs at average device settings

1

  

For more information, see the Battery/Device 

Compatibility List on www.resmed.com. 

Using 15 cm H

2

O (IPAP), 5 cm H

2

O (EPAP), and 15 BPM (Respiratory Rate). Not applicable to devices 

when using heated humidification and heated tubing.

 

Summary of Contents for RPS II

Page 1: ...User guide English...

Page 2: ...r10 fournie avec les appareils Air10 ou le convertisseur CC Air10 Pour plus d informations sur l autonomie des batteries veuillez consulter la liste de compatibilit entre les appareils et les batterie...

Page 3: ...ry coupler packed with Velcro strap Compatible devices and accessories For a full list of compatible devices for RPS II see the Battery Device Compatibility List on www resmed com on the Products page...

Page 4: ...ems with both AC and DC inputs Refer to illustration E 1 Select the correct output voltage for your device using the voltage output selector from the RPS II rear panel 2 Connect the appropriate DC out...

Page 5: ...harged DC on off B 8 Flashing blue RPS II turned on but not discharging Constant blue RPS II turned on and discharging Audible alert mute B 5 Flashing blue Not discharging and mute is active Constant...

Page 6: ...eriodically recharged ie every six months the RPS II will eventually self discharge to the point that it can no longer be recharged If this occurs the RPS II is no longer usable and is unrecoverable S...

Page 7: ...t continuously and an amber LED is flashing The battery charge level is less than 5 Press the audible alert mute button to mute the alert Recharge the battery as soon as possible RPS II sounds an audi...

Page 8: ...hPa Aircraft use Product meets the Federal Aviation Administration FAA requirements RTCA D0 160 section 21 category M for all phases of air travel Recharge time 4 hrs at full level Electromagnetic com...

Page 9: ...ice please contact your ResMed office local distributor or go to www resmed com environment General warnings and cautions WARNINGS Lithium ion batteries have built in safety protection circuits but ca...

Page 10: ...and operational If there are any defects the system should not be used The RPS II is to be used only in accordance with the intended use stated in this guide Damage to equipment or injury can result...

Page 11: ...sult of improper use abuse modification or alteration of the product b repairs carried out by any service organisation that has not been expressly authorized by ResMed to perform such repairs c any da...

Page 12: ...3 2 1 4 D 3 4 5 2 1 6 E 1 2 3b 3a F...

Page 13: ...X14 4RW UK See www resmed com for other ResMed locations worldwide For patent and other intellectual property information see www resmed com ip AirSense AirCurve H5i S9 Stellar and VPAP are trademarks...

Reviews: