ResMed RPS II User Manual Download Page 2

     i

Power Station II

DC output voltage & DC cables

24V

26V

DC Cable  

Part Number

AirSense

 10

37343

AirCurve

 10

37343

VPAP

 III ST-A

24959

VPAP

 III ST-A with QuickNav

24959

VPAP

 Auto 25

24960

VPAP

 S, VPAP

 ST

24960

S8

 Auto 25

24960

S9

 Series

24961

Stellar

™ 

Series

24959 

(24981 for Stellar

  

Mobility bag)

VS III

24963

English

Notes:

 

Not all devices are available in all regions. VPAP III ST-A with QuickNav and VS III are  
not available in the U.S.

 

To recharge the ResMed Power Station II using an Air 10 power supply unit (supplied with Air 10 
devices) or the Air 10 DC converter, an Air 10 power supply unit adaptor is required (part no. 37342).

 

For information on battery run times refer to the Battery/Compatibility List on www.resmed.com.

Français

Remarques :

 

Certains de ces appareils ne sont pas disponibles dans tous les pays. La VPAP III ST-A QuickNav et 
le VS III ne sont pas disponibles aux États-Unis.

 

L’adaptateur du module d’alimentation Air10 (code produit 37342) est nécessaire pour recharger le 
bloc d’alimentation ResMed Power Station II avec une alimentation Air10 (fournie avec les appareils 
Air10) ou le convertisseur CC Air10. 

 

Pour plus d’informations sur l’autonomie des batteries, veuillez consulter la liste de compatibilité 
entre les appareils et les batteries disponible sur www.resmed.com.

Español

Notas:

 

No pueden obtenerse todos los dispositivos en todas las regiones. El VPAP III ST-A con QuickNav y 

el VS III no están disponibles en los EE. UU.

 

Para recargar la ResMed Power Station II con una fuente de alimentación Air 10 (suministrada con 
los dispositivos Air 10) o el transformador de CC Air 10, se necesita un adaptador de la fuente de 
alimentación Air 10 (n.° de pieza 37342).

 

Para obtener información sobre la duración de las baterías, consulte la Lista de compatibilidad de 

baterías/dispositivos en www.resmed.com.

Português

Notas:

 

Nem todos os dispositivos estão disponíveis em todas as regiões. O VPAP III ST-A com QuickNav e 
o VS III não estão disponíveis nos EUA.

 

Para recarregar a ResMed Power Station II usando uma unidade de alimentação Air 10 (fornecida 
com dispositivos Air 10) ou o conversor CC Air 10, é necessário um adaptador da fonte de 
alimentação Air 10 (peça n.º 37342).

 

Para obter informações sobre a autonomia das baterias, consulte a lista de compatibilidade entre 
baterias/dispositivos em www.resmed.com.

Summary of Contents for RPS II

Page 1: ...User guide English...

Page 2: ...r10 fournie avec les appareils Air10 ou le convertisseur CC Air10 Pour plus d informations sur l autonomie des batteries veuillez consulter la liste de compatibilit entre les appareils et les batterie...

Page 3: ...ry coupler packed with Velcro strap Compatible devices and accessories For a full list of compatible devices for RPS II see the Battery Device Compatibility List on www resmed com on the Products page...

Page 4: ...ems with both AC and DC inputs Refer to illustration E 1 Select the correct output voltage for your device using the voltage output selector from the RPS II rear panel 2 Connect the appropriate DC out...

Page 5: ...harged DC on off B 8 Flashing blue RPS II turned on but not discharging Constant blue RPS II turned on and discharging Audible alert mute B 5 Flashing blue Not discharging and mute is active Constant...

Page 6: ...eriodically recharged ie every six months the RPS II will eventually self discharge to the point that it can no longer be recharged If this occurs the RPS II is no longer usable and is unrecoverable S...

Page 7: ...t continuously and an amber LED is flashing The battery charge level is less than 5 Press the audible alert mute button to mute the alert Recharge the battery as soon as possible RPS II sounds an audi...

Page 8: ...hPa Aircraft use Product meets the Federal Aviation Administration FAA requirements RTCA D0 160 section 21 category M for all phases of air travel Recharge time 4 hrs at full level Electromagnetic com...

Page 9: ...ice please contact your ResMed office local distributor or go to www resmed com environment General warnings and cautions WARNINGS Lithium ion batteries have built in safety protection circuits but ca...

Page 10: ...and operational If there are any defects the system should not be used The RPS II is to be used only in accordance with the intended use stated in this guide Damage to equipment or injury can result...

Page 11: ...sult of improper use abuse modification or alteration of the product b repairs carried out by any service organisation that has not been expressly authorized by ResMed to perform such repairs c any da...

Page 12: ...3 2 1 4 D 3 4 5 2 1 6 E 1 2 3b 3a F...

Page 13: ...X14 4RW UK See www resmed com for other ResMed locations worldwide For patent and other intellectual property information see www resmed com ip AirSense AirCurve H5i S9 Stellar and VPAP are trademarks...

Reviews: