Page:
13
User Manual:
Installation Instructions (Continued)
GAS ADJUSTMENT (CONVERSION TO LPG)
IMPORTANT!
The conversion work must be carried out by a registered gas fitter and in accordance
with the current standards.
WARNING!
Always isolate the cooktop from the electricity supply before changing the injectors and/
or adjusting the minimum flow of the burners.
→
Remove the pan-stands, burners and flame spreaders (A).
→
Unscrew the injector (B) and replace it with the stipulated injector for the new gas supply
(see table below).
GENERAL INJECTORS TABLE
KIND OF GAS
NOZZLE
MM
BURNERS
POWER (MJ/H)
MAX.
MIN.
NATURAL
1.80
1.49
1.16
0.85
Wok
Rapid
Semi-rapid
Auxiliary
14.4
10.8
6.5
3.8
6.3
5.4
3.24
1.8
L.P.G.
BUTANE
PROPANE
1.07
0.93
0.72
0.53
Wok
Rapid
Semi-rapid
Auxiliary
14.7
11.0
6.6
3.7
6.3
5.4
3.24
1.8
→
Reassemble all the burners carefully; in particular you should make sure that the flame
spreader is correctly placed on the burner.
IMPORTANT!
The minimum flow adjustment process must be completed before the appliance is next
used.