RL-DM8000 User Guide and Install Manual
Page 5
After connecting the device to the “Web Management” port located on the rear of the device and locating the device via the
‘Network’ tool in ‘My Computer’
STEP 1:
Right Click and Select “View device Webpage”.
STEP 2
: Login Select Common Setup
Once the Common Setup Tab is selected you will be prompted to enter the user name and password for device:
Encoder Programming and Setup via GUI Interface
Overview Page
Welcome page showing overview status of the Encoder when fully functioning.
Alternate between viewing status of
RF Output 1
and
RF Output 2
by selecting the RF Output section of the device you
want to monitor.
Default User Name:
admin
Default Password:
Admin123
NOTE
: Local Save
Once all parameters are set you are required to do a Local Save.
Notes on Changes:
Changes made to an individual setup tab may require the installer to perform a Local Save AND Upload and
Reboot to the device if you are only making changes to one parameter to the encoder.
Example: Installer is required to change only the output channel for the device (No other changes to the device are not required).
Once the channel has been changed, the installer is required to perform
1.
Local Save
and
2.
Upload and Reboot
.