background image

3

 

 

5.

 

 

Especificações Técnicas 

 

Standards 

100Base-TX, IEEE 802.3u 
10Base-T, IEEE 802.3 

Cabos 

100Base-TX: Cat.5 TP 
10Base-T: Cat.3, 4 or 5 TP 

Taxa de Transferência de 
Dados 

100Base-TX/10Base-T: 200/100/20/10Mbps, via 
Auto-Negotiation 

Interface 

5 * 10/100Base-TX/10Base-T 
8 * 10/100Base-TX/10Base-T 

Switch Fabric 

1Gbps Capacidade de Encaminhamento 

Tabela de endereços MAC

 

1K entradas 

Temperatura 

Funcionamento - 0°C a 45 °C 
Armazenamento - 20°C a 70°C 

Umidade 

Funcionamento - 10% a 90% RH 
Armazenamento - 5% a 90% RH 

Adaptador Externo de 
Tensão 

Adaptador Externo de Tensão (DC 9V) 

Dimensões 

160 * 83 * 26mm 

Certificação 

FCC Part 15 Class A, CE 

 
 
 

6.

 

 

Solução de problemas de hardware 

 

Este capítulo contém informações para ajudar você a resolver problemas. Se o interruptor 
não está funcionando corretamente, certifique-se de que o 

switch foi montado

 de acordo com 

as instruções neste manual. 

 
 

1.  O LED de alimentação não está aceso solução: 

A. 

Verifique se o adaptador de energia DC está bem conectado. Tente desconectar e ligue novamente o 
adaptador de energia para o comutador de LAN ou tente usar outro adaptador de alimentação.   

B. 

Verifique se a fonte de alimentação de CC está em bom estado. 

 
 

2.  O LED do link não estiver aceso a solução: 

A. 

Certifique-se de que o interruptor de configuração é compatível com o dispositivo de ligação. 

B. 

Verifique as conexões de cabo.   

C.  Certifique-se de que a distância do cabo entre o interruptor e o outro dispositivo de rede compatível com 

IEEE802.3 não deve exceder 100 metros. 

 
 

3.  O desempenho é mau solução: 

A. 

Verifique o 

estado

 de full duplex o switching de Ethernet. Se a comutação Ethernet é definido como full 

duplex e o parceiro está definido para o modo half duplex, então o desempenho será insatisfatório.   

B. 

Certifique-se de que o cabo entre o interruptor e o outro dispositivo de rede compatível com IEEE802.3 é 
UTP Categoria 5 em operação a 100Mbps. 

 
 

4.  Algumas estações não comunicam com outras estações localizadas noutras portas Solução: 

A. 

Verifique o 

estado

 do LED do link para ter certeza de que o link está correto.   

B. 

Certifique-se de que a configuração de rede da estação de trabalho está correto, modificar a configuração 
de rede da estação de trabalho se necessário.   

C.  Reponha o interruptor se necessário. 

Summary of Contents for RP-1705K

Page 1: ...RP 1705K RP 1708K 5 8 Port 10 100Mbps Switch Quick Installation Guide V1 0 ...

Page 2: ...talled n Cat 5e or Cat 6 Network Cable n The surface must support at least 265g for the Switch n The power outlet should be within 1 82 meters 6 feet of the Switch n Make sure that it is securely connected to the power adapter n Make sure that there is proper heat dissipation from and adequate ventilation around the Switch n Do not place heavy objects on the Switch 2 Application ...

Page 3: ...seem to work it will soon cause data loss All kinds of IEEE802 3 compatible network device Hub Switch PC can connect to the Switch by using straight through wires or crossover wires because of Switch s auto MDIX function 4 LEDs 1 Connect the AC Power Adapter to the RP 1705K RP 1708K and then to a power outlet 2 Connect a CAT 5e or CAT 6 RJ 45 network cable from the computer to an available Etherne...

Page 4: ...ry to unplug and plug back the power adapter to the LAN Switch or try another power adapter B Check if the DC power source is in good condition 2 The Link LED is not lit Solution A Make sure the Switch configuration is consistent with the connecting device B Check the cable connections C Make sure the cable distance between the Switch and other IEEE802 3 compatible network device should not exceed...

Page 5: ...RP 1705K RP 1708K 5 8 Port 10 100Mbps Switch Guia de Instalação Rápida V1 0 P N 41AR 170508KB A00 ...

Page 6: ...de instalado n Cabo de rede Cat 5e ou Cat 6 n Superfície deve suportar no mínimo 265g n A tomada elétrica deve estar a no máximo 1 82 metros 6 feet do Switch n Assegure se de que o cabo de alimentação está adequadamente conectado n Assegure se de que há ventilação adequada e dissipação de calor aproriada no entorno do Switch n Não coloque objetos pesados sobre o Switch 2 Aplicação ...

Page 7: ...cabo Categoria 3 ou 4 pode inicialmente funcionar será rapidamente causador de perda de dados Todos os tipos de dispositivo de rede compatível com IEEE802 3 Hub o switch PC podem se conectar ao switch usando cabo direto ou cruzado porque o interruptor tem a função Auto MDIX 4 LEDs 3 Conecte o Cabo de Alimentação ao RP 1705K RP 1708K e então a uma tomada elétrica 1 Conecte o Cabo de Alimentação ao ...

Page 8: ...ador de energia para o comutador de LAN ou tente usar outro adaptador de alimentação B Verifique se a fonte de alimentação de CC está em bom estado 2 O LED do link não estiver aceso a solução A Certifique se de que o interruptor de configuração é compatível com o dispositivo de ligação B Verifique as conexões de cabo C Certifique se de que a distância do cabo entre o interruptor e o outro disposit...