12
Erbas Teknoloji - Reporter MX1144-DGR/B/H User Manual
You may want to see device status automatically under some periods and make sure everything is
working properly. Reporter’s Heartbeat (or keep alive) feature makes this happen. As a factory default
it is set to 0 hours (which means function is disabled). You may set this between 0…999 Hours (more
than 40 days!).
Each keep alive message will include all inputs and outputs current status, mode selection, call
activation, keep alive current interval setting and current GSM CSQ signal level.
Authorization
:
Admins only
Format
:
Password
<space>
KA:Period
Examples
:
1111 KA:24
// Set keep alive for once per day
1111 KA:0
// Disable keep alive messages
Responses
:
Process Succeed.
// format & pass is correct
Process Failed!
// format is wrong
5.11.
Restore Factory Defaults (RESET)
Resetting the device does not mean any performance change on this device. Reset only deletes all
registered numbers and deletes all configurations & password settings. Thus, device will restore itself
into factory settings.
Authorization
:
Admins only
Format
:
Password
<space>
RESET
Examples
:
1111 RESET
// reset device
Responses
:
Process Succeed.
// format & pass is correct
Process Failed!
// format is wrong
6.
CHECK DEVICE STATUS (STATUS QUERY)
Anytime, while device is external powered, you may send a Status Query SMS to Reporter. It will reply
to you with detailed current I/O status, some settings and GSM signal level information.
Authorization
:
Admins only
Format
:
Password
<space>
STATUS
Examples
:
1111 STATUS
// ask status
Responses
:
INP1:OFF
// INP1 is OFF (LOW)
…
INP4:ON
// INP4 is ON (HIGH)
RLY1:OFF
// RLY1 is OFF (LOW)
…
RLY4:ON
// RLY4 is ON (HIGH)
MOD:1
// call mode is MOD1 (trigger mode)
CALL:OFF
// alert call feature is disabled
KA:24
// keep alive period is 24 hours
SIGNAL:26
// very good GSM signal (between 0..31)
Process Failed!
// format is wrong