Reporter A1000 User Manual Download Page 6

 

There 

should 

be 

space 

character 

between 

independent 

commands 

e.g.: 

 1111<space>NEWP:1234<space>DEL1<space>DISABLE 

Device is case sensitive; please pay attention to text message ingredients.  

Attention: If you write the password wrong  you will receive an SMS including “WRONG PSWR” text. In 
that case device will keep in configuration mode. Please wait until LED becomes solid again and send a 
configuration  SMS  with  correct  password.  Otherwise  device  will  keep  the  same  settings  and  continue 
operation after 2 minutes timeout and LED will become OFF. 

Below is the list of commands: 

DESCRIPTION 

COMMAND 

DEFAULT 

Change Password 

NEWP:XXXX 

1111 

Add / Change User1 

TEL1:+XXXXXXXXXX 

 

Add / Change User2 

TEL2:+XXXXXXXXXX 

 

Delete User1 

DEL1 

 

Delete User2 

DEL2 

 

Enable Keep Alive 

ENABLE 

Enabled (Weekly) 

Disable Keep Alive 

DISABLE 

Enabled (Weekly) 

Reset Device 

RESET 

 

 

Table – 1 “Commands List” 

EXAMPLE: 
 

1111 NEWP:5555 TEL1:+906661234567 TEL2:+907771234567 DISABLE 
 
Above example means: 
 

o

 

New admin password is now “5555” and you have to use this new password to make new 
configurations in the future. Please note it carefully. 

o

 

You added a new user1 906661234567.  

o

 

You added a new user2 907771234567.  

o

 

Weekly keep alive messages are disabled. 

Once you sent this SMS to your device, it will reply you with an SMS including “CONFIG OK <XX>” 
text (where XX is GSM signal strength, see “Table-2” for further details). Now LED will turn off and 
your device is ready to operate. 

Finally close the cover and insert screws on the back. 

<XX> 

MEANING 

ADVICE 

Between 19~31 

Excellent Signal 

 

Between 14~18 

Good Signal 

 

Between 9~13 

Workable Signal 

Try changing location  

Between 1~8 

Weak Signal 

Check antenna / change device location 

 

Table – 2 “GSM Signal Strength Levels” 

 

 

 

Summary of Contents for A1000

Page 1: ...1 USER MANUAL A1000 REV2 1 1604 FW A1000v2 93 A1000 GSM ALARM DEVICE ERBAŞ TEKNOLOJİ Innovative Solutions www erbasteknoloji com ...

Page 2: ...m case Other usages are not permitted Police fire or healthcare emergency call lines are not permitted to call directly from this device Do not configure emergency call numbers into this device BATTERY RECYCLING CR123A batteries are classified as recycled batteries Please take your empty batteries to a nearest collection point BATTERY LIFE Battery life announced by manufacturer is calculated under...

Page 3: ...tion or not Below list shows the feedbacks from your device NO Port Failure Text Message PORT1 ALARM and phone call ring NO Port Restored Text Message PORT1 OK and phone call ring NC Port Failure Text Message PORT2 ALARM and phone call ring NC Port Restored Text Message PORT2 OK and phone call ring Power Failure Text Message POWER FAIL Power Restored Text Message POWER OK Low Battery Text Message ...

Page 4: ...otection o Send an SMS to a mobile number for testing o Call a mobile phone number for testing After above steps please open the screws on the back of the item And please insert SIM card into your device by opening the SIM card holder Once SIM card is inserted please lock the holder 2 2 Connect Sensors on Ports Note Wires should pass into the holes of the top cover Please check Wiring Diagram NO P...

Page 5: ...d insert batteries only 2 4 Register Admin Number Admin number is authorized to make configurations change delete settings of the device And also will receive all alerts with SMS and or phone calls Other users will only receive alerts and will not be able to make configurations The LED will blink a few times until it is connected to an available network Please wait for LED becomes solid ON Once LE...

Page 6: ...ENABLE Enabled Weekly Disable Keep Alive DISABLE Enabled Weekly Reset Device RESET Table 1 Commands List EXAMPLE 1111 NEWP 5555 TEL1 906661234567 TEL2 907771234567 DISABLE Above example means o New admin password is now 5555 and you have to use this new password to make new configurations in the future Please note it carefully o You added a new user1 number 906661234567 o You added a new user2 num...

Page 7: ...d not inserted Remove batteries and adaptor Insert SIM card first and then power device PIN code not disabled Remove batteries adaptor and then SIM card Insert SIM card into a mobile phone Disable SIM Card PIN protection from settings Insert SIM card to your device first and then power device Signal level not enough below 13 Change device location or try with another GSM operator until finding goo...

Page 8: ...ort Failure SMS Call in case of NO Port Restored SMS Call in case of NC Port Failure SMS Call in case of NC Port Restored SMS for Power Failure SMS for Power Restored SMS for Low Battery SMS for Keep Alive Messages SMS for GSM Signal Strength while configuration Configurations via SMS Change security password Register delete user phone numbers up to 2 Enable disable weekly keep alive messages Rese...

Reviews: