NC PORT (Port2): Connect two wires of your NC type device output or cable into terminal block 7 & 8.
It does not matter which one is first. This port is a “Normally Closed” port and checks if there is any
open-circuit between terminal 7 & 8.
Device ports are digital and device provides required port voltage by itself. Do not apply any external
power on these terminal blocks which might cause damages. Also make sure that your external device
does not apply any voltage, or sink or sank any currents. Your external device should only provide a dry
contact relay output or short or open circuit (i.e. switches, NO/NC sensors).
2.3.
Connect Power
Connect 12V DC power adaptor into terminal block numbers 1 and 2. Number 1 is positive (+12V) and
2 negative (GND).
Note: Wires should pass into the holes of the top cover! Please
check Wiring Diagram!
C12V of power adaptor to the terminal block 1 (usually
RED wire).
Connect GND of power adaptor to the terminal block 2 (usually
BLACK wire).
Please note power adaptor current should be at least 1000 mA.
Then insert two pieces of CR123A batteries included in the package. (If power adaptor is not used,
insert batteries only).
2.4.
Register Admin Number
Admin number is authorized to make configurations, change & delete settings of the device. And also will
receive all alerts with SMS and/or phone calls. Other users will only receive alerts and will not be able to
make configurations.
The LED will blink a few times until it is connected to an available network. Please wait for LED
becomes solid ON. Once LED is ON; that means device is connected to a GSM network and ready to
work.
Now please call the device’s number with your phone. Once you hear the ringing volume, your
number is registered to devices memory as ADMIN NUMBER.
Then the LED will blink and device will send you an SMS including “ADMIN OK” message. Once you
received this message that means device is ready to work and now operating! If you want to make
some changes on settings please continue from below steps.
2.5.
Send Configuration Commands
Press config button for 3 seconds and wait LED becomes solid ON. Now your device is waiting for a
configuration SMS from you (note that timeout is 2 minutes).
Please note all commands should start with an admin password (except RESET command). Default
password is “1111”. Also, it is possible to send one or several commands in one SMS.
Commands should be written in “big letters” (correct one: 1111 NEWP:3333, wrong one is: 1111
newp:3333).