4) MANUAL STARTING PROCEDURE OF REGENARATION
Based on customer requirements, a regeneration process can be started manually at any time. In this case, you will notice
that, during the regeneration process, the softener will deliver unsoftened water.
To proceed with manual regeneration, follow the steps below:
Press and hold the buttons at the same time
for 5 seconds until you hear the beep and the key pad is unlocked.
Press the button
and immediately the regeneration process will start.
2.2.6 SECTION FOR TECHNICAL PERSONNEL
It is possible to access the programming of the regeneration times in the various phases.
Changing these settings defined by the manufacturer seriously compromises the functionality of the softener, so please do
not do so.
If these settings have been changed by the customer, you can reset the original data as follows:
REGENERATION CONTROL MODE
A – 01
FREQUENCY OF COUNTER-CURRENT WASHING
F – 00
QUANTITY OF SOFTENED WATER
m3
Millennium 8 (0.55)
Millennium 12 (1.10)
WASHING TIME COUNTER-CURRENT
m3
2 – 01
BRINE ASPIRATION TIME/WASH
3 – 20 (Millennium 8)
3 – 40 (Millennium 12)
BRINE TANK FILLING
4 – 04 (Millennium 8)
4 – 06 (Millennium 12)
FAST WASHING
m3
5 – 03
MAXIMUM REGENERATIVE INTERVAL (IN DAYS)
m3
H - 03
OUTPUT MODE
m3
b - 01