2.0 Functions
Inputs:
Terminals
Set-point 1
Voltage set-point:
or power set-point:
0...10 V, DC, 0(4)...20 mA or Potentiometer 10 k
11(-), 13(+), 14(+10Vref.)
11(-), 12 (+) with 4...20 mA
Set-point 2
Current set-point:
0...10 V, DC, 0(4)...20 mA or Potentiometer 10 k
15(-), 17(+),
18(+10Vref.)
15(-), 16(+) with 4...20 mA
Inhibit
(SMP CP & CP/M
48-10 /-20
)
Contacts or 24 V, DC signal voltage
42(-), 43(+),
41 (-0Vref.), 44(+24Vref.)
Inhibit
(SMP CP & CP/M
24-5
)
Contacts or 24 V, DC signal voltage
42(+),
41 (
–ref.), 43 (+ref.)
Outputs:
Effective value 1
Effective output voltage 4…20 mA
31(-), 32(+)
Effective value 2
Effective output current 4…20 mA
33(-), 34(+)
Status relay
(SMP CP & CP/M
48-10 /-20
)
Status ON / OFF (output), change over contact
51, 52, 53
Inhibit
(SMP CP & CP/M
48-10 /-20
)
:
Potential free input via optocoupler to terminals 42 and 43.
External contact across terminals 43 and 44 and a link between 41 and 42 or external 24 V, DC signal on
terminals 42(-) and 43(+).
Inhibit
(SMP CP & CP/M
24-5
)
:
External contact across terminals 42 and 43 or external 24 V, DC signal on terminals 41(-) and 42(+).
Voltage regulation (set-point 1)
Link set-point 2 (current) to +10V reference (terminals 17 and 18).
Set-point power to 100% or nominal value. (Menu C 020, P. =100%)
Connect voltage set-point to terminals 11
– 14 (see connection diagram).
The current limit can be set in Menu “C. 020”.
Current regulation (set-point 2)
Link set-point 1 (voltage) to +10 V reference (terminals 13 und 14).
Set-point power to 100% or nominal value. (Menu C 020, P. =100%)
Connect current set-point to terminals 15
– 18 (see connection diagram).
The maximum output volt
age can be set in Menu “C. 020”.
Power regulation (set-point 1) Switching to power regulation: set in Menu C 003: E.F.P. = I
Link set-point 2 (current) to +10V reference (terminals 17 and 18).
Set-point voltage to 100% or nominal value. (Menu C 020, P. =100%)
Connect power set-point to terminals 11
– 14 (see connection diagram).
The current limit can be set in Menu “C. 020”.
Summary of Contents for REOTRON SMP CP 24-5
Page 1: ...SMP CP M_ANL_EN_rev04 05 01 2017 REOTRON SMP CP SMP CP M DC Power supply ...
Page 15: ...REOTRON SMP CP CP M Instruction manual 15 7 0 Dimensions REOTRON SMP CP 24 5 ...
Page 16: ...REOTRON SMP CP CP M Instruction manual 16 REOTRON SMP CP M 24 5 ...
Page 17: ...REOTRON SMP CP CP M Instruction manual 17 REOTRON SMP CP 48 10 20 ...
Page 18: ...REOTRON SMP CP CP M Instruction manual 18 REOTRON SMP CP M 48 10 20 ...