Application Development in Flexisoft
®
27
5) User can add tasks to update PLC tags information. Tasks supported for GWY-9xx are as follows:
Task Name
SMS Screen Tasks
Main loop Tasks
Before
While
After
Power
Global Task
Showing
Showing
Hiding
On Task
Screen
Screen
Screen
Goto Screen
YES
NO
YES
YES
NO
Previous Screen
YES
NO
YES
NO
NO
Next Screen
YES
NO
YES
NO
NO
Switch Screen from Tag
YES
NO
YES
YES
YES
Write value to Tag
YES
YES
YES
YES
YES
Add a constant value to Tag
YES
YES
YES
YES
YES
Subtract a constant value form TagYES
YES
YES
YES
YES
Add Tag B to Tag A
YES
YES
YES
YES
YES
Subtract Tag B to Tag A
YES
YES
YES
YES
YES
Turn Bit On
YES
YES
YES
YES
YES
Turn Bit Off
YES
YES
YES
YES
YES
Toggle Bit
YES
YES
YES
YES
YES
Copy Tag B to Tag A
YES
YES
YES
YES
YES
Swap Tag A and Tag B
YES
YES
YES
YES
YES
Copy HMI block to HMI/PLC block YES
YES
YES
YES
YES
Copy HMI/PLC block to HMI block YES
YES
YES
YES
YES
Copy Tag to LED
NO
NO
NO
NO
NO
Wait While
NO
YES
NO
NO
NO
Delay
NO
YES
NO
NO
NO
Key Specific Tasks
NO
NO
NO
NO
NO
USB Data Log Upload
NO
NO
NO
NO
NO
6) Go to SMS screen.
User supposed to write message/s on SMS Screens. Using Objects like Text, Numerical data display, Mes-
sage data display & Bit data display, user can form maximum 160 character single message on SMS Screen.
Similarly, user can add different messages on different screens for different parameters.
To send the SMS keep default option “Print once and Display Screen option” to the right, as shown below:
Summary of Contents for GWY-900