Rentech Jaguar 1.2K User Manual Download Page 3

 

1. Introduction 

Thank you for purchasing this inverter. This simple inverter is designed to power your home appliances or 
precious 3C electronics. It also can handle motor-type loads with high surge power such as vacuums, small 
freezers, or drills.   
This manual is for qualified personnel. The tasks described in this manual may be performed by qualified 
personnel only. 

 

2. Important Safety Warning (SAVE THESE INSTRUCTIONS) 

Before using the inverter, please read all instructions and cautionary markings on the unit, this 
manual and the batteries. 
 

 

 

 
General Precaution- 
CAUTION!

 The unit is designed for indoor use. Do not expose this unit to rain, snow or liquids of any type. 

CAUTION! 

To reduce risk of injury, only use qualified batteries from qualified distributors or manufacturers. 

Any unqualified batteries may cause damage and injury. Do NOT use old or overdue batteries. Please check the 
battery type and date code before installation to avoid damage and injury. 

CAUTION! 

Authorized service personnel should reduce the risk of electrical shock by disconnecting AC, DC and 

battery power from the inverter before attempting any maintenance or cleaning or working on any circuits 
connected to the inverter. Turning off controls will not reduce this risk. Internal capacitors can remain charged 
for 5 minutes after disconnecting all sources of power. 

CAUTION! 

Do not disassemble this inverter yourself. It contains no user-serviceable parts. Attempt to service 

this inverter yourself may cause a risk of electrical shock or fire and will void the warranty from the 
Manufacturer. 

CAUTION! 

To avoid a risk of fire and electric shock, make sure that existing wiring is in good condition and that 

the wire is not undersized. Do not operate the Inverter with damaged or substandard wiring. 

CAUTION! 

To reduce risk of fire hazard, do not cover or obstruct the cooling fan. 

CAUTION! 

Do not operate the inverter if it has received a sharp blow, been dropped, or otherwise damaged in 

any way. If the inverter is damaged, called for an RMA (Return Material Authorization). 

WARNING:

 There are no user-replaceable parts inside of the inverter. Do not attempt to service the unit 

yourself. 

WARNING! 

It's very important for system safety and efficient operation to use appropriate external battery 

cable. To reduce risk of injury, external battery cables should be UL certified and rated for 105°C or higher. And 
do not use copper cables less than 6AWG or 10AWG*2. 

 

CAUTION! 

Do not disassemble the inverter. Contact with the qualified service center when service or repair is 

required. 

WARNING! 

Provide ventilation to outdoors from the battery compartment. The battery enclosure should be 

designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment. 

CAUTION!

 Use insulated tools to reduce the chance of short-circuit when installing or working with the inverter, 

the batteries, or other equipments attached to this unit.   

CAUTION! 

For battery installation and maintenance, read the battery manufacturer's installation and 

maintenance instructions prior to operating. 

 
Personnel Precaution -   

CAUTION! 

Careful to reduce the risk or dropping a metal tool on the batteries. It could spark or short circuit the 

batteries and could cause an explosion. 

CAUTION!

 Remove personal metal items such as rings, bracelets, necklaces, and watches when working with 

batteries. Batteries can produce a short circuit current high enough to make metal melt, and could cause severe 
burns. 

CAUTION! 

Avoid touching eyes while working near batteries. 

CAUTION!

 Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes. 

Conventions used: 
WARNING! 

Warnings identify conditions or practices that could result in personal injury;   

CAUTION!   

Caution identify conditions or practices that could result in damaged to the unit or other 

equipment connected. 

Summary of Contents for Jaguar 1.2K

Page 1: ...USER MANUAL J A G U A R B AT T E RY B O X 1 2kVA 900W 2 4kVA 1600W s a l e s p o w e r p r o v i d e r c o z a w w w p o w e r p r o v i d e r c o z a ...

Page 2: ...Table of Contents 1 Introduction 1 2 Important Safety Warning SAVE THESE INSTRUCTIONS 1 3 Product Overview 3 4 Installation 3 5 Operation 5 6 Trouble Shooting 10 7 Specifications 11 ...

Page 3: ... cover or obstruct the cooling fan CAUTION Do not operate the inverter if it has received a sharp blow been dropped or otherwise damaged in any way If the inverter is damaged called for an RMA Return Material Authorization WARNING There are no user replaceable parts inside of the inverter Do not attempt to service the unit yourself WARNING It s very important for system safety and efficient operat...

Page 4: ...ke or allow a spark or flame in vicinity of a battery CAUTION If a remote or automatic generator start system is used disable the automatic starting circuit or disconnect the generator to prevent accident during servicing ...

Page 5: ...automatically charge the internal battery even though the unit is off Connect to Battery Pack 1 2k Model Follow below steps to connect battery pack Step 1 Take out top case by removing screws as shown below chart 1 Power switch 2 Status indicator 3 Charging indicator 4 Fault indicator 5 Function buttons Please see the Operation section for the details 6 LCD display 7 AC input 8 AC output receptacl...

Page 6: ...t to connect battery pack Step 3 Insert battery pack inside of cabinet Assemble top case to original position 2 4k Model Follow below steps to connect battery pack Step 1 Take out top case by removing screws as shown below chart ...

Page 7: ...e power switch again the unit will be turned off LED Indicators Function Keys Audible Alarms There are three indicators in the front panel of the unit LED Indicator Messages Green Solid On Output is available in bypass mode Flashing Output is powered by battery in inverter mode Green Solid On Battery is not charging Flashing Battery is charging Red Solid On Fault mode Flashing battery low or overl...

Page 8: ...mation Indicates the Battery level by 0 24 25 49 50 74 and 75 100 in battery mode charging status in line mode In AC mode it will present battery charging status Status Battery voltage LCD Display Constant Current mode Constant Voltage mode 11Vdc pcs 4 bars will flash in turns 11Vdc 11 5Vdc pcs Bottom bar will be on and the other three bars will flash in turns 11 5Vdc 12 5Vdc pcs Bottom two bars w...

Page 9: ...mode Escape 01 AC input voltage range Wide default If selected acceptable AC input voltage range will be within 90 280VAC Narrow If selected acceptable AC input voltage range will be within 170 280VAC 02 Battery type AGM Default Flooded User defined 03 Max AC charging current 20A default 10A 04 Bulk charging C V voltage voltage 12V model default setting 14 1V 24V model default setting 28 2V If sel...

Page 10: ...ill be fixed to setting value no matter what percentage of load is connected Display Setting The LCD display information will be switched in turns by pressing SCROLL key The selectable information is switched as below order input voltage battery voltage output voltage load percentage load in Watt and main CPU Version Selectable information LCD display Selectable information LCD display Input volta...

Page 11: ...e Mode The unit will provide output power from the mains It will also charge the battery at line mode Charging by utility Battery Mode The unit will provide output power from battery Power from battery only Fault Reference Code Fault Code Fault Event Icon on Fault Code Fault Event Icon on 00 Output short circuit 05 Fan locked 01 Over load time out 06 Over temperature 03 Output voltage too high 08 ...

Page 12: ...on the front panel when the utility power is normal No LED display Battery is not connected well Check the external battery cable and terminal Make sure all the battery connections to the unit are all correct Battery defect Replace the batteries Buzzer beeps continuously and red LED is on Fault code 00 Output short circuited Check if wiring is connected well and remove abnormal load Fault code 01 ...

Page 13: ... 10A 13A Maximum Output Fault Current 6 9A 13 6A Transfer Time 20 ms typical Waveform Simulated Sine Wave BATTERY Battery Type and Numbers 12 V 100Ah x 1 12 V 100Ah x 2 Maximum Battery Discharging Current 76A 76A Floating Charge Voltage 13 7 VDC 0 5 VDC 27 4 VDC 1 VDC Maximum AC Charging Current 10 A or 20 A 10 A or 20 A PHYSICAL Dimension DxWxH mm 393 250 459 345 400 450 Net Weight kgs 40 5 75 8 ...

Page 14: ......

Reviews: