18
en
Fixscreen
®
100
EVO
Solar
The closed type side channel is pre-drilled as standard (the inner chamber by Ø10 mm in all
cases). There are 2 placement options for the side channel:
sideways
or v
ia the rear wall
. The
Ø10 mm borehole is already pre-drilled; the ø5 mm borehole has yet to be drilled.
• We strongly advise to secure the box to the construction by using counter sunk screws and
avoid each contact with the fabric on the left hand side and right hand side
• Always secure the box as close as possible at the groove.
In case of a width > 3 m, extra fixation of the box in the middle is obligatory.
• The fixation needs to be done on the extremities of the box, as close as possible towards the
side brackets of the box and in the middle of the width of the screen.
• Use counter sunk screws to seal the box.
4
The holes are pre-drilled sequential over a distance of 250mm.
Allow a maximum distance of 750 mm between sequential holes.
Fix the screws and make sure that the screw head is integrated (flush-mounted)
to prevent obstruction of the H-PVC inner rail.
3
Mounting of side channel
through the backside (ø5mm)
Mounting of side channel
sideways (ø5mm)