![Renogy Rover 100A Manual Download Page 8](http://html1.mh-extra.com/html/renogy/rover-100a/rover-100a_manual_1442919008.webp)
07
The purpose for this is to offset the power consumption while maintaining a full battery storage
capacity. In the event that a load drawn from the battery exceeds the charge current, the
controller will no longer be able to maintain the battery to a Float set point and the controller will
end the float charge stage and refer back to bulk charging.
Equalization:
Is carried out every 30 days of the month. It is intentional overcharging of
the battery for a controlled period of time. Certain types of batteries benefit from periodic
equalizing charge, which can stir the electrolyte, balance battery voltage and complete
chemical reaction. Equalizing charge increases the battery voltage, higher than the standard
complement voltage, which gasifies the battery electrolyte.
Once equalization is active in the battery charging, it will not exit this stage unless
there is adequate charging current from the solar panel. There should be NO load
on the batteries when in equalization charging stage.
Over-charging and excessive gas precipitation may damage the battery plates
and activate material shedding on them. Too high of equalizing charge or for too
long may cause damage. Please carefully review the specific requirements of the
battery used in the system.
Equalization may increase battery voltage to a level damaging to sensitive DC
loads. Ensure that all load allowable input voltages are greater than the equalizing
charging set point voltage.
WARNING
WARNING
WARNING
The Rover MPPT charge controller has a reactivation feature to awaken a sleeping lithium
battery. The protection circuit of lithium battery will typically turn the battery off and make it
unusable if over-discharged. This can happen when storing a lithium battery pack in a
discharged state for any length of time as self-discharge would gradually deplete the remaining
charge. Without the wake-up feature to reactivate and recharge batteries, these batteries would
become unserviceable and the packs would be discarded. The Rover will apply a small charge
current to activate the protection circuit and if a correct cell voltage can be reached, it starts a
normal charge.
Lithium Battery Activation
Summary of Contents for Rover 100A
Page 1: ...Rover 100A Version 1 4 Maximum Power Point Tracking Solar Charge Controller ROVER SERIES ...
Page 12: ...1 Remove Cover 2 Connect Battery 3 Connect Solar Panels 11 ...
Page 34: ...3 48 Volt System Conversion Efficiency 2 24 Volt System Conversion Efficiency 33 ...
Page 35: ...34 NOTE Dimensions in millimeters mm Dimensions 443 320 270 280 4Xφ8 4Xφ12 110 50 ...