Renogy LYCAN 5000 Quick Manual Download Page 6

03

Product Overview

COMMU

NICATI

ON

AC INPUT

20A

AC OUTPUT

20A

AC/INV 

SET 

UP 

DOWN 

ENT 

CHARG

E  FAU

LT 

SOLAR

 INPUT

 1

SOLAR

 INPUT

 1

+

+

AC OUTPUT

30A

SOLA

R 1

SOLAR

 2

BATTE

RY

SURCE 

AC OUTPUT

 20A 

AC OUTPUT

 30A 

AC OUTPUT

 30A 

PROTECTION 

BLUETOOTH 

POWER 

LINK 

BT-2 

Bluetooth

 Modul

1

2

3

4

5

6

7

8

9

10

11

6

12

13

14

NO.

Part

NO.

Part

1

Solar Inverter Charger Display 

(Including Indicators and Buttons)

8

Viewing Window

2

Solar Input Circuit Breaker 1

9

Bluetooth Module

3

Solar Input Circuit Breaker 2

10

AC Output Circuit Breaker (20A)

4

Battery Circuit Breaker

11

AC Output Circuit Breaker (30A)

5

Surge Protection Device

12

AC Input Circuit Breaker (20A)

6

Front Door Locks

13

AC Outlet (30A)

7

AC Inlet (20A)

14

AC Outlet (20A)

Summary of Contents for LYCAN 5000

Page 1: ...P DOWN ENT CHARGE FAULT SOLARINPUT1 SOLARINPUT1 AC OUTPUT 30A SOLAR 1 SOLAR 2 BATTERY SURCE AC OUTPUT 20A AC OUTPUT 30A AC OUTPUT 30A PROTECTION BLUETOOTH POW ER LIN K BT 2 Bluetooth Module VERSION A1...

Page 2: ...Scan for the User Manual...

Page 3: ...nstallation 05 Turning On 07 Charging 08 AC Charging 08 Solar Charging 09 Powering Appliances 11 Temporary Power Supply 11 Off Grid Living 13 Emergency Backup 15 Bluetooth Pairing 19 Turning Off 20 Ca...

Page 4: ...th Mod ule Quick Guide 1 IEC C19 to NEMA 5 20P Power Cable 1 Keys 2 VERSION A1 Power Box LYCAN 5000 RPB4835OA 48LFPA12S QUICK GUIDE COMMUNICATIO N AC INPUT 20A AC OUTP UT 20A AC INV SET UP DOWN ENT CH...

Page 5: ...0Ah Smart Lithium Iron Phosphate Battery Solar Array 1 Solar Array 2 z This Quick Guide contains important installation operation and maintenance instructions for LYCAN 5000 Power Box Please read the...

Page 6: ...lue tooth Mod ule 1 2 3 4 5 6 7 8 9 10 11 6 12 13 14 NO Part NO Part 1 Solar Inverter Charger Display Including Indicators and Buttons 8 Viewing Window 2 Solar Input Circuit Breaker 1 9 Bluetooth Modu...

Page 7: ...ng Waterproof Housing 18 Back Door Locks 23 Vent Cover 19 Handle Bar Installation Required 24 Swivel Casters z Please inspect the unit for any visible damage including cracks dents deformation and oth...

Page 8: ...than 2 inches COMMU NICATIO N AC INP UT 20A AC OU TPUT 20A AC INV SET UP DOWN ENT CHARGE FAULT SOLAR INPUT 1 SOLAR INPUT 1 AC OU TPUT 30A SOLA R 1 SOLA R 2 BATTE RY SURC E AC OUTP UT 20A AC OUTP UT 3...

Page 9: ...0A AC OUT PUT 30A AC OUT PUT 30A PRO TECT ION BLU ETO OTH POWER LINK BT 2 Bluetoot h Module 1 6 AC OUTPUT 30A Lift LYCAN from the skid with two people Release the Pedal Brakes on Swivel Casters Move L...

Page 10: ...puncture or incinerate the battery it the external contacts 122 50 C F battery to temperatures above BATTERY 48V 50AH BATTERY 1s 2 5 Bluetooth Module LINK POWER BLUETOOTH SET UP DOWN ENT AC INV CHARG...

Page 11: ...TEC TIO N BLU ETO OTH POWER LINK BT 2 Blueto oth Modul e 3 1 2 Connect LYCAN to a wall outlet or a generator not included with the included Power Cable Loosen the captive screws to open the Viewing W...

Page 12: ...TIO N BLU ETO OTH POWER LINK BT 2 Blueto oth Modul e 3 2 2 Connect the solar panels sold separately in series and or parallel to form solar arrays Connect the solar arrays to the Solar Connectors of L...

Page 13: ...ating voltage mismatches or partial shading can cause current backflow and damage solar arrays z Press the Solar Inverter Charger UP and DOWN Buttons to turn the page and view detailed charging status...

Page 14: ...UT 2 EXPANSION Connect the Power Strips not included with corresponding current ratings to the 20A and 30A AC Outlets of LYCAN Plug appliances into the Power Strips AC INPUT 20A AC I NV SET UP DOW N E...

Page 15: ...0A AC Outlet is used to power appliances the continuous loads shall not exceed 16A and the noncontinuous loads shall not exceed 20A z When the 30A AC Outlet is used to power appliances the continuous...

Page 16: ...busbar not included Connect the bare wire end of the Adapter Cable not included to the AC Load Center The black live wire goes to either of the live terminals L the white neutral wire goes to the neu...

Page 17: ...Powered by Bypass AC Powered by Batteries Push the switch on the 30A AC Output Circuit Breaker up The Solar Inverter Charger AC INV Indicator lights up yellow when the appliances are powered by bypas...

Page 18: ...ct the bare wires from the Transfer Switch sold separately to the AC load center The white neutral wire goes to the neutral busbar N and the green ground wire goes to the grounding busbar PE I ON O OF...

Page 19: ...1 2 1 2 X G Y W Y X W G 4 3 7 Remove the cover and the power inlet filler plate of the Transfer Switch Connect the green ground wire included in the Transfer Switch to the grounding terminal of the Tr...

Page 20: ...INK BT 2 Bluet ooth Modu le 4 3 12 AC OUTPUT 20A AC OUTPUT 30A AC INPUT 4 3 13 METER 1 METER 2 GEN OFF GEN OFF LINE LINE A B C D E F 4 3 14 Loosen the captive screws to open the Viewing Window Push th...

Page 21: ...ase use an automatic transfer switch instead z Please close the Viewing Window and tighten the captive screws after completing the steps above z The continuous loads shall not exceed 24A and the nonco...

Page 22: ...the Back Door Locks with the included Keys and rotate the wing knobs counterclockwise by 90 to open the back door Locate the communication hub Unplug either of the Ethernet cables connected to the se...

Page 23: ...s counterclockwise by 90 to open the front door Locate the switch on the bottom of the solar inverter charger Turn the switch to the OFF position O The Solar Inverter Charger Indicator goes out after...

Page 24: ...and Back Door Lock after turning LYCAN off z If LYCAN is not going to be used for a long time and neither solar nor AC power are available to keep LYCAN topped off please turn LYCAN off to prevent the...

Page 25: ...the user manual of 48V 50Ah Smart Lithium Iron Phosphate Battery at renogy com carefully before connecting additional Batteries to LYCAN z DO NOT connect more than 6 Batteries to LYCAN z The Anderson...

Page 26: ...he UP communication port of the first Battery to the RJ45 Jack of LYCAN with the Ethernet Cable AC INPUT 20A AC OUTPUT 20A SOLARINPUT1 SOLARINPUT1 AC OUTPUT 30A 48V 50AH BATTERY COMMUNICATION COMMUNIC...

Page 27: ...to the fan and displays the temperature of the air vent Inspection Please perform regular inspections by following the steps below z Examine the external appearance of LYCAN The enclosure and connecto...

Page 28: ...e the battery in an open well ventilated dry clean area with temperatures between 32 F 104 F 0 C 40 C z DO NOT expose LYCAN to extreme temperatures z Engage the Pedal Brakes on Swivel Casters to preve...

Page 29: ...for grid power Live Sustainably with Renogy Did you know In a given month a 1KW solar energy system will Save 170 pounds of coal from being burned Save 300 pounds of CO2 from being released into the a...

Page 30: ...notice Visit renogy com to nd the User Manual or get more support via Contact Us Your voice matters Scan the QR code to submit your feedback on the product Join the Renogy Power Plus Community by dow...

Reviews: