Setting Battery Charger
Please Note: The battery charger is for lithium-iron phosphate battery types with a built in BMS system.
Do not use the device
under any circumstances
to charge other types of batteries
(ex. NiCd, NiMH, etc.).
WARNING: Danger of Explosion! *Note: Check the charging requirements from the battery
manufacturer before charging your battery with this unit.
*Note, make sure to abide by the safety instructions in the beginning of the manual
The DCDC is equipped with 5 DIP switches which determine the boost charge and float charge profiles,
depending on your battery specifications. Refer to the diagram for ON/OFF position respectively.
DIP Switch
Description
S5
Determines whether the charging
profile will be for Lithium batteries or
for others battery types
S1, S2
Determines the Constant Voltage for
your battery charging profile
S3, S4
Determines the Float Voltage for your
battery charging profile
*This will not be used for lithium
batteries
Start with SW5 to determine whether you are charging a lead-acid battery or lithium
ON
ON
OFF