SINGLE
CH ANNEL LOOP DETECTOR
OPERATING INSTRUCTIONS
I
General
The Model BX-LP is a low power loop detector for solar or low power installations. To minimize power
consumption the detector’s
DET
(Detect) LED will only light during the three minutes immediately following
initial power-up or detector reset. After the three minutes the
DET
(Detect) LED is will not light, but the detector
continues to function normally.
Please verify source voltage before applying power.
The model designation indicates the input power required
and output configuration for the detector as follows:
Model BX-LP-xx
Blank = 12 VDC with Relay Outputs
24
= 24 VDC with Relay Outputs
SS
= 12 VDC / 24 VDC with Solid State Outputs
The input voltage range, and current consumption figures for the various versions of the detector are listed in the
table below.
Relay Outputs
Solid State Outputs
Model
BX-LP
BX-LP-24
BX-LP-SS
Input Voltage
10 to 14 VDC
20 to 28 VDC
10 to 28 VDC
Current
Consumption*
3.3 to 7.0 mA in No Detect State
35 to 40 mA in Detect State
(Output A Presence / Output B Pulse)
60 to 65 mA in Detect State
(Output A Presence / Output B Presence)
3.3 to 7.0 mA**
NOTES:
* Current consumption is a function of the sensitivity. See the table in the "Front Panel Rotary
Switch (Sensitivity)" section for actual current draw at each of the sensitivity settings.
** Add 6.0 mA for each lit (DET and/or Fail) LED.
II
Indicators and Controls
i
Detect / Fail LEDs
The detector has two red LED indicators that are used to provide an indication of the detector’s output state
and/or loop failure conditions. The
DET
(Detect) LED is only activated during the three minutes immediately
following initial power-up or detector reset. The table below lists the various indications and their meanings.
Status
DET (Detect) LED
FAIL (Loop Fail) LED
Off
Output(s) Off
Loop OK
On
Output(s) On
N/A
Flash
4 Flashes per Second
(50% duty cycle)
Two second timing delay activated
1 Hz (50% duty cycle)
Loop Failure
One flash every five seconds
Prior Loop Failure
NOTE:
The
DET
(Detect) LED will only turn on or flash during the three minutes
immediately following initial power-up or reset of the detector. After the three
minutes immediately following initial power-up or detector reset, the Detect
LED is deactivated, but the detector continues to function normally. The
FAIL
(Loop Fail) LED provides the indications shown above at all times.