Point Source Array Modules
10
Rear Panel Connections & Controls
Array Module High Frequency Control
Not all setups are identical and neither are all rooms. That is why the VX101
series modules can include a rear mounted high frequency level control.
The high frequency level control allows you to adjust the high frequency output
of each array module to compensate for:
1. Increased loss of high frequency energy from air loss over distance
2. Increased coupling between array modules at low frequencies
3. Different room sizes and acoustics
They allow you to maintain the proper High/Mid/Low frequency balance
throughout the listening area. As a general rule use “Flat” when working with a
single cabinet, plus 6 when using 2 cabinets in a small array and plus 9 in arrays
having 3 or more cabinets.
You can also set the upper cabinets in an array to +9 dB and the bottom one to
+6 dB or Flat to optimize the coverage.
High Frequency Level Control
VX101 Connections
Screw Terminal
Strip Inputs
Looping In & Out
Neutrik 4-Pin
Speakon Connectors
VX101 modules require bi-amplification. An optional passive crossover network is available.
VX15S subwoofers are shipped wired for fully passive operation using the internal crossover. The crossover can be bypassed by
removing the connector plate from the cabinet and changing several internal connections. For detailed instructions, please refer
to the Renkus-Heinz Loudspeaker User’s Manual, form RH508.