12
Hinge Kit Brackets
Install versions of the ICLive X series can be mounted to a
wall with a hinge kit mounting system. The hinges are pintle
and gudgeon separable hinges. The male, pintle, half mounts
to the wall or other supporting structure, the female, gud-
geon, half mounts to the loudspeaker cabinet.
Once the pintle halves are mounted to the supporting struc-
ture, the loudspeaker mounts by sliding the gudgeon over the
pintle. The loudspeaker can be aimed horizontally through a
75 degree arc. The pintles can be installed on either side of
the hinge wall brackets, allowing the ICLive X array to aim to
either side. When the desired aiming is achieved, the lock-
angle rod on the bottom hinge is used to secure the aiming.
ICLive X Hinges are sold under two part numbers:
• HK-ICLX: Includes two hinges, the minimum needed
to wall mount an ICLive X Array.
• HK-ICLX-1:Single additional hinges for installing
larger ICLive X Arrays.
The hinges are shown in red in the accompanying drawings.
Hinge Kit Guidelines and Instructions
• The maximum number of cabinets in an array that will
be supported by the hinges is six ICLX or a combina-
tion of ICLX and ICLXL/ICLLX of equivalent height. An
array taller than the equivalent of six ICLive X, will
require the use of RHANG fly-bars.
• The minimum number of hinges to mount a single
cabinet is two. For multi-cabinet arrays, the number
of hinges should equal the number of cabinets in the
array. (ICLXL-ICLLX arrays require three hinges.) The
hinge position at the top or bottom of any individual
cabinet in the array may be used to accommodate lo-
cal mounting needs. Always use a hinge at the bottom
of the array for the lock-angle rod.
• The hinges will be packaged separately from the
loudspeaker cabinets. Once you have determined the
locations on the cabinets where the hinges will be
used, remove the three M6 bolts from the back of the
loudspeaker, just above or below the amplifier.
• Place the hinge plate with the female gudgeons in
place with the openings facing down.
• Reinstall the 6 mm bolts using thread locking com-
pound and tighten securely.
75°
75°