background image

Controls

1

6

4

5

3

8

7

9

10

11

2

2

1  Master socket (this controls all 9 slave sockets)
2  Slave sockets (7x protective contact sockets, 2x Euro mains sockets)
3  Main switch (“0” = off, “I” = on), controls all 10 sockets
4   Reset button, switches the power supply on again when the overload protection has tripped (switch off 

the outlet strip via the main switch first and let it cool down)

5  Control lamps
 

 “Überspannungsschutz (Overvoltage protection)”: Lights up when the overvoltage protection is active

 

“Slave An (Slave on)”: Lights up when the 9 slave sockets are activated

6   Setting control to adjust the switching threshold from 8 - 80 W (if the power consumption at the master 

socket falls below the set limit, the consumer loads connected to the 9 slave sockets (2) are switched 

off; if the set limit is exceeded, the consumer loads are switched on again)

7   Fuse holder for replaceable microfuse T2.5 A (the fuse blows when the power consumption of a con-

sumer load connected to the master socket is too high)

8   Switch “Mater ein/aus (Master on/off)” (for switching between master/slave function and continuous 

operation of all sockets)

9   RJ11 sockets with voltage surge protection (please pay attention to the arrows when connecting inputs 

and outputs).

10   RJ45 sockets with voltage surge protection (please pay attention to the arrows when connecting inputs 

and outputs).

11   TV sockets with voltage surge protection (please pay attention to the arrows when connecting inputs and 

outputs).

Getting started/operation

  Follow the safety instructions in these operating instructions!

•  If the outlet strip is placed on a desk or on the floor, use an appropriate mat to protect valuable surfaces 

from scratches. 

•  Plug the earthed mains plug of the outlet strip into a regular earthed mains socket (wall socket).
•  Connect the consumer loads to the outlet strip. 

a) Operation without master/slave function

•  Set the switch “Master ein/aus (Master on/off)” (8) to the position “Master ein (Master on)”. The LED “Slave 

An (Slave on)” lights up and stays on permanently. 

•  All the sockets (and the consumer loads connected to them) are switched on/off via the main switch (3). 

When turned on (switch position “I”), a red control light comes on in the main switch.

b) Operation with master/slave function

•  Set the switch “Master ein/aus (Master on/off)” (8) to the position “Master aus (Master off)”.
•  Turn the setting control with a small screwdriver gently to the left (counter-clockwise) to the position “8 W”.
•  Connect the consumer load which is meant to control the slave sockets to the master socket. Please note 

that the power consumption of the master device should not exceed 550 W (during normal operation the 

device must have a power consumption of at least 8 W so that the master/slave switching process can be 

activated).

•  Switch off the consumer load connected to the master socket. The LED “Slave An (Slave on)” should now 

turn off. 

  Should this not be the case (the master device consumes more than 8 W in standby mode or when 

switched off), turn the setting control (6) for the switching threshold slowly clockwise until the LED “Slave 

An (Slave on)” turns off. The loads connected to the 9 slave sockets are now switched off.

•  Switch on the consumer load connected to the master socket. The LED “Slave An (Slave on)” should now 

turn on. 

   Depending on how the power consumption of the consumer load connected to the master socket 

changes during operation, it may be necessary to readjust the setting control (6) until the desired 

switching operation of the slave sockets works seamlessly.

Replacing the fuse

The fuse (7) blows when the power consumption of the consumer load connected to the master socket is 

too high.

   Disconnect the earthed mains plug from the mains socket (wall socket). Otherwise, there is a 

risk of a life-threatening electric shock!

Unscrew the fuse holder by turning it all the way to the left (counter-clockwise).
Replace a blown fuse by a fuse of the same type and rating (5 x 20 mm microfuse, T2.5 A, 250 V). 

   Never use a fuse with higher current rating. Never bridge a defective fuse! There is a risk of fire 

and a life-threatening electric shock!

Insert the new fuse into the fuse holder. Insert the fuse holder with the fuse into the outlet strip and screw 

it back in its place.

Maintenance and cleaning

•  The product does not require maintenance. The product contains no parts that require servicing. There-

fore, do not open/dismantle it. Maintenance or repair work may be performed only by qualified personnel 

or a specialised repair shop. 

•  Switch off the outlet strip and disconnect it from the mains voltage before cleaning. 

   Disconnect the earthed mains plug from the mains socket (wall socket). 

  Also disconnect all connected loads from the outlet strip.
•  To clean the product, a clean, dry and soft cloth is sufficient. 
•  Dust can be easily removed using a clean, soft and long-bristled brush and a vacuum cleaner. 

   Do not use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since these 

could damage the casing or even impair operation. 

Disposal

  This symbol must appear on any electrical and electronic equipment placed on the EU market. 

This symbol indicates that this device should not be disposed of as unsorted municipal waste at 

the end of its service life.

Owners of WEEE shall dispose of it separately from unsorted municipal waste. Spent batteries and accu-

mulators, which are not enclosed by the WEEE, as well as lamps that can be removed from the WEEE in a 

non-destructive manner, must be removed by end users from the WEEE in a non-destructive manner before 

it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free takeback of waste. 

Conrad provides the following return options free of charge (more details on our website):
•  in our Conrad offices
•  at the Conrad collection points
•  at the collection points of public waste management authorities or the collection points set up by manu-

facturers or distributors within the meaning of the ElektroG

End users are responsible for deleting personal data from the WEEE to be disposed of. It should be noted 

that different obligations about the return or recycling of WEEE may apply in countries outside of Germany.

Technical data

Operating voltage ..........................................250 V/AC, 50 Hz
Connected load ............................................. Master socket: Max. 550 W (max. 2.5 A) 

For 9 slave-sockets: Max. 1700 W (max. 7.4 A) in total 

For all 10 sockets: Max. 3680 W (max. 16 A) in total

Mains switch ..................................................2-pole, with integrated red control light
Cable length ..................................................1.5 m
Voltage surge protection ................................ yes, integrated for sockets RJ11, RJ45 and TV aerial socket
Leakage current .............................................12 kA
Fuse for master socket ..................................Microfuse 5 x 20 mm, 250 V, T2.5 A 
Ambient temperature .....................................0 °C to +40 °C
Ambient humidity ...........................................0% to 80% relative humidity, non-condensing
Dimensions ....................................................370 x 157 x 54 mm (L x W x H)
Weight ...........................................................approx. 1170 g (incl. cable)

   Slight variations in dimensions and weight are dependent on the production technique.

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-

cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represents the technical status at the time of printing.
Copyright 2022 by Conrad Electronic SE. 

*2541577_v2_0222_02_dh_mh_3L