PWR1

PWR2

•  Connect the 6-pin terminal block to the terminal input (4).
• 

Connect one end of the terminal power supply leads (not 

included) to PWR1 or PWR2 on the terminal block, and 

connect the other end to the power supply.

•  The power leads should be wired to the 6-pin power 

terminal block matching polarities as marked. 

• 

Check the LED 

PWR1 / PWR2

 (1) on the front panel to make sure that any powered switches 

are receiving power.

c) Place on DIN Rail

• 

The DIN rail has to comply with EN 55022 (overall width 3.5 cm, overall height 0.75 cm). The 

roduct may not be installed on any other mounting rails!

• 

Place the product on the DIN rail and secure it in place.

d) Network Cable Connection

•  Use suitable network cables to connect devices and computers to the switch ports.
•  All network ports supports auto uplink, which means that no crosslink cables are necessary 

to connect multiple network switches.

•  Make sure the cables are not bent or crushed.
•  We recommend to mark the network cables with suitable adhesive labels or other devices. 

This will allow you in case of a fault to know perfectly which connections need to be checked.

Operation

a) DIP Switches (Alarm Control)

• 

Switch 1 to 8 (ports 1 to 8). If these DIP switches are ON, 

Alm 

LED

 (6) will activate if a network connection is severed.

• 

Switch 9 (power inputs 

PWR1 / PWR2)Alm 

LED

 (6) will turn 

ON if 

PWR1 or PWR2 fails.

b) Alarm Relay

• 

The switch has a single 24 V/DC, 1 A alarm relay output, and can be set to trigger when a 

network connection is severed a source of 

power (

PWR1 / PWR2) fails or both.

•  Alm

 LED 

(6) will blink and the alarm relay will trigger a few seconds later.

PWR1

PWR2

ALM

• 

To deactivate the alarm, set the related DIP switch to 

the OFF position.

• 

To reactivate the alarm, set the related DIP switch to 

the ON position after the alarm conditions have been 

removed.

c) LED Indicators

LED

Colour

Status

Description

PWR1 / PWR 2

Green

ON

Receiving power

Green

OFF

No power received

Alm

Red

ON

Port link down or power failure

Red

OFF

No event

SFP

Green

ON

SFP connected

Green

OFF

No SFP connected

Green

Flashing

Network activity

Link/Act

Green

ON

Link active

Green

OFF

Link inactive

Green

Flashing

Network activity

Port speed

Amber

ON

Item No. 1697435: 1000 Mbit/s
Item No. 1697437: 100 Mbit/s

Amber

Flashing

Item No. 1697435: 10/100 Mbit/s
Item No. 1697437: 10 Mbit/s

Care and Cleaning

• 

Disconnect the product from the mains before each cleaning.

• 

Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as it 

can cause damage to the housing and malfunctioning.

• 

Clean the product with a dry, fibre-free cloth.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the 

household waste. At the end of its service life, dispose of the product in accordance 

with applicable regulatory guidelines.

You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical Data

Specification

Item No. 1697435

Item No. 1697437

Input voltage

2x (12 - 24 V/DC) via removable 

6-pin terminal block

2x (12 - 24 V/DC) via removable 

6-pin terminal block

Output relay (alarm) 24 V/DC, 1A

24 V/DC, 1A

Power consumption

max. 8 W

max. 8 W

MAC address

4 K

4 K

Ports

6 x RJ45 (Gigabit)
2 x SFP (Gigabit)

6 x RJ45 (Fast Ethernet)
2 x SFP (Gigabit)

Buffer memory

4 Mb

4 Mb

IEEEE

IEEE 802.3 – 10BaseT
IEEE 802.3u - 100BaseTX
IEEE 802.3ab - 1000BaseT

IEEE 802.3z 1000 Base SX/LX

IEEE 802.3x - Flow Control

IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX

IEEE 802.3z 1000 Base SX/LX

IEEE 802.3x - Flow Control

EMI

FCC Class A Part 15, VCCI 

Class A

FCC Class A Part 15, VCCI 

Class A

EMS

EN61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-8

N61000-4-2 (ESD)
EN61000-4-3 (RS)
EN61000-4-8

IEC

IEC60068-2-27 (shock), 

IEC60068-2-32 (freefall), 

IEC60068-2-6 (vibration)

IEC60068-2-27 (shock), 

IEC60068-2-32 (freefall), 

IEC60068-2-6 (vibration)

Filtering/forwarding 

rates

11.904 Mpps

3.87 Mpps

RJ45 transmission

10 BaseT Cat. 3, 4, 5 UTP/STP
100 BaseTX Cat. 5 UTP/STP
1000 BaseT Cat. 5E UTP/STP

10 BaseT Cat. 3, 4, 5 UTP/STP
100 BaseTX Cat. 5 UTP/STP

SFP transmission

62.5/125 μm Multi Mode Fiber 

optic cable, max. 220 m

50/125 μm Multi Mode Fiber 

optic cable, max. 550 m

9/125 μm Single Mode Fiber 

optic cable

62.5/125 μm Multi Mode Fiber 

optic cable, max. 220 m

50/125 μm Multi Mode Fiber 

optic cable, max. 550 m

9/125 μm Single Mode Fiber 

optic cable

LED indicators

PWR1, PWR2, Alm, 1000M, 

Link/Act

PWR1, PWR2, Alm, 10/100M, 

Link/Act

Ingress protection 

rating (housing)

IP30

IP30

Mounting

DIN-rail

DIN-rail

Operating 

Temperature

-40 to +70 °C, 5 – 95 % relative 

humidity (non-condensing)

-40 to +70 °C, 5 – 95 % relative 

humidity (non-condensing)

Storage 

temperature

-40 to +85 °C, 5 – 95 % relative 

humidity (non-condensing)

-40 to +85 °C, 5 – 95 % relative 

humidity (non-condensing)

Dimensions 
(H x W x D)

55 x 120 x 108 mm

55 x 120 x 108 mm

Weight

0.56 kg 

0.57 kg

Summary of Contents for 1697435

Page 1: ...bit SFP Switch für Hutschiene 6 2PortFastEthernet SFPSwitchfürHutschiene Best Nr 1697435 Best Nr 1697437 Bestimmungsgemäße Verwendung Bei diesem Produkt handelt es sich um einen 6 2 Port Gigabit Best Nr 1697435 6 2 Port Fast Ethernet Best Nr 1697437 mit SFP Switch gemäß Industriestandard der für kleine bis mittlere Netzwerkumgebungen konzipiert ist Er ist kompakt hat einen weiten Betriebstemperatu...

Page 2: ...aktivieren stellen Sie den entsprechenden DIP Schalter auf Position OFF Um den Alarm wieder zu aktivieren stellen Sie den entsprechenden DIP Schalter nach dem Entfernen der Alarmbedingungen auf Position ON c LED Anzeigen LED Farbe Betriebszustand Beschreibung PWR1 PWR 2 grün EIN Spannung liegt an grün AUS Keine Spannungsversorgung Alm rot EIN Portverbindung unterbrochen oder Stromausfall rot AUS K...

Page 3: ...et SFP Switch for DIN Rail Item No 1697435 Item No 1697437 Intended Use This product is an industrial 6 2 Port Gigabit Item 1697435 6 2 Port Fast Ethernet Item 1697437 with SFP switch that is designed for small to medium sized network environments It is compact has a broad operating temperature range and comes with a DIN rail mount The switch has redundant power supply for situations where an alte...

Page 4: ...onnected Green Flashing Network activity Link Act Green ON Link active Green OFF Link inactive Green Flashing Network activity Port speed Amber ON Item No 1697435 1000 Mbit s Item No 1697437 100 Mbit s Amber Flashing Item No 1697435 10 100 Mbit s Item No 1697437 10 Mbit s Care and Cleaning Disconnect the product from the mains before each cleaning Do not use any aggressive cleaning agents rubbing ...

Page 5: ...it ne reçoive aucune alimentation électrique tant que l installation n est pas terminée Mode d emploi Interrupteur Gigabit 6 2 Commutateur SFP pour rail DIN Interrupteur Fast Ethernet 6 2 Commutateur SFP pour rail DIN N de commande 1697435 N de commande 1697437 Utilisation prévue Ce produit est un interrupteur industriel Gigabit industriel 6 2 ports n de commande 1697435 Fast Ethernet 6 2 ports n ...

Page 6: ... l alarme mettez l interrupteur DIP concerné sur la position Arrêt Pour réactiver l alarme mettez l interrupteur DIP concerné sur la position Marche après que les causes de déclenchement de l alarme aient été résolues c Indicateurs LED LED Couleur État Description PWR1 PWR2 Vert MARCHE Reçoit de l électricité Vert ARRÊT Ne reçoit aucune électricité Alm Rouge MARCHE Liaison avec le port interrompue...

Page 7: ...van de schakelkast waar de netwerkschakelaar is geïnstalleerd Gebruiksaanwijzing 6 2 Poorts Gigabit SFP Schakelaar voor DIN Rail 6 2 Poorts Snel Ethernet SFP Schakelaar met voor DIN Rail Bestelnr 1697435 Bestelnr 1697437 Beoogd gebruik Dit product is een industriële 6 2 Poorts Gigabit bestelnr 1697435 6 2 Poorts Snel Ethernet bestelnr 1697437 metSFP schakelaar ontworpenvoorkleinetotmiddelgrotenetw...

Page 8: ...IP schakelaar op de stand AAN in te stellen nadat de alarmcondities zijn geëlimineerd c LED indicators Led Kleur Status Beschrijving PWR1 PWR 2 Groen AAN Voeding wordt ontvangen Groen UIT Geen voeding ontvangen Alm Rood AAN Poortlink verbroken of stroomuitval Rood UIT Geen gebeurtenis SFP Groen AAN SFP verbonden Groen UIT Geen SFP verbonden Groen knipperen Netwerkactiviteit Link Act Groen AAN Link...

Reviews: