Renishaw RGH40 Installation Manual Download Page 5

RGH40 installation drawing

Dimensions and tolerances in mm

RGH40 RGS40-G

 

installation guide

3

Arrow indicates forward direction of 

readhead relative to scale

R>50 Dynamic bend radius 

R>10 Static bend radius

Scale graduations

2 mounting holes M3 x 9.5 deep

Reference mark sensor position

Optical centreline

Reference mark actuator  

(A-9531-0250)

P limit magnet  

(

A-9531-0251)

 

Mount dimple down 

(Dimensions same as Q limit)

 

P limit switch 

sensor position

Arrow indicates optical and  

reference mark centreline

(Roll tol. ±1°)

Q limit magnet  

(A-9531-0251)

 

Mount dimple up for Q

Optional bolted limit magnet 

(A-9550-0047)

,  

(A-9550-0048)

Mounting ledge or  

top surface of bracket  

for limit switch actuator

(Pitch tol. ±1°)

0.8

0.8

7.5

10.5

Q limit switch  

sensor position

10

14.6

17.5

25.5

Optional bolted limit magnet

3

7

14

4

6 min

(Yaw tol. ±1°)

20.7

15.3

3.6

5.7

8.6

*

Set-up  

LED

0.13

27

9

18

2.9

4.9

4.05

8.5

7.7

5.1

14.4

Ø4.5 ±0.2

44

38

3

2 mounting holes 
M3 x 7.5 deep

2.9

17

2.8

3

13

14.6

4

Rideheight 

0.8 ±0.15

0.5 ±0.5

*

Extent of mounting faces.

The recommended thread engagement is 5 mm. The recommended tightening torque is between 0.5 and 0.7 Nm.

Summary of Contents for RGH40

Page 1: ...Installation guide M 9550 9023 01 A RGH40 RGS40 G linear encoder system...

Page 2: ...ss scale installation drawing clip clamp mounting 6 Clip clamp mounting installation 7 Reference mark actuator installation 8 Limit switch installation 8 Readhead mounting and alignment 8 Reference ma...

Page 3: ...tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOTE This unit was tested wi...

Page 4: ...cal encoder scale that provides good immunity against contaminants such as dust fingerprints and light oils However in harsh environments such as machine tool applications protection should be provide...

Page 5: ...es optical and reference mark centreline Roll tol 1 Q limit magnet A 9531 0251 Mount dimple up for Q Optional bolted limit magnet P A 9550 0047 Q A 9550 0048 Mounting ledge or top surface of bracket f...

Page 6: ...6 5 2 9 4 10 3 18 8 5 4 05 17 5 25 5 12 5 27 5 ML 47 ML 44 L ML 14 5 L 25 n 1 4 9 2 9 10 12 RGG 2 2 part epoxy usually coincident with user selected scale datum Double sided adhesive tape Bolted P lim...

Page 7: ...to cure fully then clean scale using Renishaw scle wipes A 9523 4040 or a clean dry lint free cloth Adhesive mounting installation 2 Mark area for epoxy on adhesive tape 1 RGH40 RGS40 G installation...

Page 8: ...x 6 5 14 5 M3 x 0 5 x 6 5 23 5 0 1 34 4 10 3 18 8 5 4 05 17 5 25 5 12 5 27 5 5 5 Datum clamp Mounting clip 4 9 2 9 Dimensions and tolerances in mm RGS40 G glass scale installation drawing clip clamp m...

Page 9: ...ean dry lint free cloth M 9550 0057 gap setting shim 4 Ensure scale can move so free to expand contract 1 2 mm 1 2 mm M 9550 0057 gap setting shim M 9550 0061 datum pad RGH40 RGS40 G installation guid...

Page 10: ...able conformance to the installation tolerances allow adjustment to the rideheight of the readhead and be sufficiently stiff to prevent deflection or vibration of the readhead during operation For eas...

Page 11: ...way D type plug L 12 way circular V 12 way circular coupling W 16 way in line connector X Power 5 V Brown 4 2 2 A Brown link 5 12 12 M 0 V White 12 10 10 B White link 13 11 11 N Incremental signals V1...

Page 12: ...ers must ensure they comply with the lowest recommended counter input frequency Encoder velocity m s Resolution m x 4 safety factor Function Signal Colour 15 way D type plug D 16 way in line connector...

Page 13: ...d from each other If the inner and outer shields are connected together this will cause a short between 0 V and earth which could cause electrical noise issues Electrical connections Grounding and shi...

Page 14: ...P Resolution S A B Z Inverse signal not shown for clarity Synchronised pulse Z duration as resolution S Repeatability of position uni directional maintained within 10 C from temperature at time of pha...

Page 15: ...ealing IP50 Acceleration Operating 500 m s2 3 axes Shock Non operating 1000 m s2 6 ms sine 3 axes Vibration Operating 100 m s2 max 55 Hz to 2000 Hz 3 axes Mass Readhead 50 g Cable 38 g m Cable 12 core...

Page 16: ...our main website at www renishaw com contact M 9550 9023 01 RENISHAW and the probe symbol used in the RENISHAW logo are registered trade marks of Renishaw plc in the United Kingdom and other countrie...

Reviews: