EVOLUTE RTLA50-S installation guide
5
RTLA50-S (with adhesive datum clamp) installation drawing
Dimensions and tolerances in mm
NOTE:
All dimensions applicable when using EVOLUTE side cable outlet version.
Overall length (L + 37)
Datum clamp
(A-9585-0028)
Optional end cover
(Pair A-9585-0035)
8
A
Readhead optical detector position at extent of travel
8.25
16.5
Scale length (L)
Measuring length ML = (L-17)
5
Optical centreline
Detail A
5
C
B
Detail C
Detail B
0.8
3.5
2.0 B
B
End cover
alignment
indicato
r
START
FINISH
12
12.5
4.5
Ra 3.2
0.5
F
0.2/100
F = axis of motion
0.05
F
F = axis of motion