14
Front panel design
2
Front panel description
The diagram below shows the front panel of the
SPA
2
:
Key
1. Axes status LEDs
2. ESTOP
LED
3. Air cooling fan inlet
2.1 Axes status LEDs
2.1.1
LED positions and axis link 3 axis / 6 axis
These LEDs indicate the status of the servo engagement within the
SPA
2
unit as shown in the table
below:
Axis status LED colour
System status
Off
The
SPA
2
has no power being applied to the system
Orange
The servo system is active but not engaged for this axis
Green
The servo system is engaged for this axis
Red
There is a fault on this axis of the system
Status 1 indicates the status of axis 0 and 1, status 2 indicates the status of axis 2 and 3 (if fitted), status 3
indicates the status of axis 4 and 5 of a 6 axis system and status 4 indicates the status of axis 6.
2.2 ESTOP LED
This red LED indicates if the emergency stop system has been activated.
2.3 Air cooling fan inlet
The
SPA
2
requires air cooling, the inlet being through this fan.
The airflow to the fan must not be obstructed. A minimum of 50 mm clearance in front of the fan is
required.