4.13
Trig
g
er Logic
RMP400 – RMI-Q partnership
System set-up is achieved by using Trigger Logic™ and powering on the RMI-Q or applying ReniKey.
Partnering is required during initial system set-up. Further partnering will be required if either the
RMP400 or RMI-Q is changed.
Partnering will not be lost by reconfiguring the probe settings or changing the batteries. Partnering can
take place anywhere within the operating envelope.
An RMP400 that is partnered with the RMI-Q but then used with another system will need to be
repartnered before being used again with the RMI-Q.
In configuration mode, configure the probe settings as required until you reach the “
Acquisition
mode
” menu, which defaults to “
Acquisition mode off
”.
Deflect the stylus to select
“
Acquisition
mode on”
. Ensure this is done within
60 seconds of the RMI-Q system status
LED flashing green.
The probe is now in standby
and the system is ready for use.
> 20 s
×
SYSTEM STATUS LED
RMI-Q in acquisition mode
with empty probe location
Acquisition mode
Acquisition mode off
Switch on the RMI-Q
SYSTEM STATUS LED
RMI-Q in acquisition mode
with full probe location
or
SYSTEM STATUS LED
Acquisition pending
Displayed for 5 seconds
NOTE:
Refer to the
RMI-Q radio
machine interface
installation
guide (Renishaw part no.
H-5687-8504) when partnering up
to four radio probes.
SYSTEM STATUS LED
New radio probe partnered
or
SYSTEM STATUS LED
Radio probe cleared from location