- 1 -
FAQ - English
For chapter indications, refer to the complete instruction manual on the internet.
Twister evolution (Nr. 1828)
Error
Cause
Solution
ON/OFF switch fails to
work.
• Power not connected.
• Check the power supply.
• Device fuse blown.
• Replace the fuse (Sec. 7.4).
Motor fails to start.
• Motor fault.
• Have the device repaired.
No, or insufficient vac
-
uum (not in the green
range on the scale).
•
Suction filter system plugged.
•
Have filter cleaned or changed (Sec. 7.3).
• Seal surfaces dirty.
• Clean the seal surfaces (Sec. 7.2).
• Solenoid valve fault.
• Have the device repaired.
•
Vacuum pump fault.
• Have the device repaired.
Vacuum release / vent
-
ing, too slow.
•
Suction filter system plugged.
•
Have filter cleaned or changed (Sec. 7.3).
• Solenoid valve fault.
• Have the device repaired.
Vacuum pump doesn‘t
start.
•
Bowl detection pin sticking.
• Clean area around pin.
• Have the device repaired.
The vacuum pump
switches on and off
intermittently during
the mixing process.
•
At <100 % vacuum, the vacu
-
um pump will switch off once
the set vacuum has been
reached.
•
None, If the vacuum should drop due to
seepage, the vacuum pump will automat
-
ically switch back on until the set vacuum
level has been reached.
Twister evolution venturi (Nr. 1829)
Error
Cause
Solution
ON/OFF switch fails to
work.
• Power not connected.
• Check the power supply.
• Device fuse blown.
• Replace the fuse (Sec. 7.4).
Motor fails to start.
• Motor fault.
• Have the device repaired.
No, or insufficient
vacuum.
•
Compressor switched off.
•
Switch the compressor on.
•
Operating pressure too low or
too high.
•
Check dynamic operating pressure
(see technical data, Sec. 9).
•
Switch off other consumers.
•
Compressed air hose not con
-
nected, leaky or bent.
• Check the hose.
•
Air hose too long.
•
Maximum length 2 m.
• Square are of air hose too
small.
•
Minimum inner diameter 4 mm.
•
Suction filter system plugged.
•
Have filter cleaned or changed (Sec. 7.3).
• Seal surfaces dirty.
• Clean the seal surfaces (Sec. 7.2).
•
Inlet filter plugged.
•
Change inlet filter (Sec. 7.5).
•
Silencer plugged.
• Replace the silencer (Sec. 7.6).
•
Connect filter pressure regulator in se
-
ries.
• Solenoid valve fault.
• Have the device repaired.
•
Venturi nozzle plugged.
• Have the device repaired.
Vacuum release / vent
-
ing, too slow.
•
Suction filter system plugged.
•
Have filter cleaned or changed (Sec. 7.3).
•
Silencer plugged.
• Replace the silencer. (Sec. 7.6).
•
Connect filter pressure regulator in se
-
ries.
• Solenoid valve fault.
• Have the device repaired.
EN