- 11 -
5.3 Programming
The menu function enables various extractor settings to be preset and saved.
In order to set different parameter, press the menu key (30) repeatedly.
To confirm and save the adjusted settings press the enter button (40).
An audible signal confirms that the settings have been successfully saved.
If you do not wish to save the adjustments, press the menu key again (30) and the programming will be
aborted.
If the word “default” is shown in the display (42) press the buttons and (41, 43) together to revert
to the standard factory settings (see table in chapter 6.5).
5.3.1 Self Diagnosis
The diagnosis symbol (31) shows whether the self diagnosis has been activated or not:
⇒
Press menu key (30) 1 x .
♦
The diagnosis symbol (31) blinks.
⇒
Switch the self diagnosis ON or OFF using the / buttons (41, 43).
⇒
Press the enter button (40).
5.3.2 Audible Signal
Various settings and warnings are confirmed or alerted via an audible signal. This signal can be
switched on or off. The audible signal symbol (32) shows whether the signal is on or off.
⇒
Press menu key (30) 2 x.
♦
The audible signal symbol (32) blinks.
⇒
Switch the self diagnosis ON or OFF using the / buttons (41, 43).
⇒
Press the enter button (40).