9.1 Intake Filter

1. Switch the device off.
2. Unscrew the intake filter (Fig. 21).

3. Clean the filter in an ultrasound bath (we recom-

mend

GO-2011

 plaster solvent, Art. No. 2011-0000).

4. Reinstall the intake filter (Fig. 21).

Never operate the device without the

intake filter!

9.2 Seal Surfaces

The following seal surfaces must always be kept clean
in order to ensure correct vacuum built up and the
secure retention of the mixing bowl during the mixing
process:

a) Seal between the device and the paddle (Fig. 22a);
b) Seal between the paddle and the bowl Fig. 22b).

Tip:

You should regularly coat the rubber seals with
Vaseline. This will significantly increase their
service life and optimize to unit’s function.

9.3 Replacing the Device Fuses

1. Unplug the device from the power supply (Fig. 13).
2. Unscrew the fuse holder (Fig. 23)

Device fuse:

Twister pro, 

230 V = T 2 A

Twister pro

, 120 V = T 4 A

3. Remove the old fuse and install the new one

(Fig. 24).

4. Reinstall the fuse holder (Fig. 23).

10. Spare Parts

Please refer to the enclosed spare parts list for all
consumables and spare / replacement parts.

11. Warranty

Provided the unit is properly used, Renfert warrants
the

Twister pro

 for a 

period of 3 years

.  Components

subject to natural wear (e.g., paddles, mixing bowls,
and intake filters) are excluded from this warranty. The
warranty is voided in case of improper use; failure to
observe the operating, cleaning, maintenance, and
connection instructions; in case of independent
repairs or repairs by unauthorized personnel; if spare
parts from other manufacturers are employed, or; in
case of unusual influences or influences not in
compliance with the utilization instructions. Warranty
service shall not extend the original warranty.

12. Technical Specifications

Mains voltage:

230 V, 50-60 Hz,
120 V, 50-60 Hz

Protection class in
accord. with IEC 536:

I

Power consumption:

190 W

Speed:

150 to 600 rpm

Device fuses:

T 2 A (

Twister

 230 V)

T 4 A (

Twister

 120 V).

Capacity:

15 l/min.

Vacuum,  max.:

approx. 200 mbar, absolute

Dimensions (WxHxD): 140 x 325 x 225 mm

[5.516 x 12.805 x 8.865 inch]

Weight:

10.1 kg, without mixing bowl

13. Standard Delivery

1

Twister pro

 vacuum mixer

1 Mixing bowl, 500 ml, incl. paddle
1 Set of Operating Instructions
1 Spare parts list
1 Drill template
1 Mounting set

14. Delivery Versions

No. 1821-0000

Twister pro

, 230 V, 50-60 Hz,

incl. 500 ml mixing bowl with paddle

No. 1821-1000

Twister pro

, 120 V, 50-60 Hz,

incl. 500 ml mixing bowl with paddle

15. Accessories

No. 1821-0100 Stand for benchtop device

WxHxD: 230 x 680 x 290 mm
[9.062 x 26.772 x 11.426 inch]

No. 1820-0200 Bowl, incl. paddle

200 ml

No. 1820-0210 Paddle

200 ml

No. 1820-0220 Mixing bowl

200 ml

No. 1820-0500 Bowl, incl. paddle

500 ml

No. 1820-0510 Paddle

500 ml

No. 1820-0520 Mixing bowl

500 ml

No. 1820-0700 Bowl, incl. paddle

700 ml

No. 1820-0710 Paddle

700 ml

No. 1820-0720 Mixing bowl

700 ml

Summary of Contents for 1821-0000

Page 1: ... 78247 Hilzingen Germany Tel 49 7731 8208 0 Fax 49 7731 8208 70 info renfert com www renfert com MadeinGermany Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones para el servicio Gebruiksaanwijzing Instrukcja obsługi Инструкция по эксплуатации ...

Page 2: ...s for damages or warranty if The product is employed for any purposes other than those cited in the operating instructions The product is altered in any way other than those alterations described in the operating instructions The product is repaired by other than an authorized facility or if any but Renfert OEM parts are employed The product continues to be employed despite obvious safety faults T...

Page 3: ... control button to start mixing Fig 20 7 The device will beep when mixing has been completed 8 To remove the mixing bowl press the control button Fig 20 Caution Hold the bowl securely The bowl will be released in a few seconds 6 3 Interrupting the Mixing Process 1 To stop the motor press the control button once Fig 20 2 To shut off the vacuum press the control button again Fig 20 Caution Hold the ...

Page 4: ...s voided in case of improper use failure to observe the operating cleaning maintenance and connection instructions in case of independent repairs or repairs by unauthorized personnel if spare parts from other manufacturers are employed or in case of unusual influences or influences not in compliance with the utilization instructions Warranty service shall not extend the original warranty 12 Techni...

Page 5: ...ying on the unit x Intake filter plugged x Clean the filter refer to Sec 9 1 Error in vacuum Vacuum builds up too fast paddle is staying on the unit but mixing bowl not x Passage openings in the paddle are plugged x Clean the paddle Error in vacuum No or insufficient vacuum mixing bowl and paddle are not staying on the unit x Seal surfaces dirty x Vacuum pump fault x Vent valve fault x Clean the s...

Page 6: ...1 3 2 4 6 5 10 12 11 7 9 8 0 3546 0 394 inch ...

Page 7: ...13 15 14 16 17 19 21 20 22 24 23 18 a b ...

Page 8: ...t 78247 Hilzingen Germany We hereby declare that the construction type of the vacuum mixer Twister pro conforms to the following relevant regulations EC guideline 98 37 EC guidelines on machines Other relevant EC guidelines 73 23 EWG on low voltage 89 336 EWG on EMC Harmonised specifications applied DIN 45635 1 DIN EN 61010 2 051 DIN EN 61326 National specifications applied ZH1 1 19 Hilzingen 19 0...

Page 9: ... 119 Hilzingen 19 03 02 EG Zgodność z normami Renfert GmbH Industriegebiet 78247 Hilzingen Germany Niniejszym objaśniamy że sposób produkcji mieszadła próżniowego Twister pro odpowiada następującym przepisom EG wytyczne 98 37 EG normy maszynowe Dotyczących wytycznych EG 73 23 EWG wytyczne niskiego napięcia 89 336 EWG zgodność elektromagnetyczna EMV Użyte zgodne z normami DIN 45635 1 DIN EN 61010 2...

Page 10: ...tton for the associated parameter PROGRAMM 1 Mixing time 1 25 Action Procedure Display Turn the control knob Parameter selection Attachment 1 Editing Setting Program Parameters English if you have finished yout input continue with 6 6 Note Speed interval pre vacuum and post vacuum are programmed analogue to the mixing time example name refer toAttachm 2 mixing time 0 5 min Please observe the manuf...

Page 11: ...he program you wish to change for 3 sec Settings Name PROGRAMM 1_ 2 5 Again briefly press the knob Edit mode Settings Name PROGRAMM 1 7 Briefly press the control knob Saves the new letter Settings Name GROGRAMM 1 Exit the parameter input mode Press the program button for the associated parameter Plaster 1 Mixing time 0 30 10 9 Exit the Name parameter Move the cursor over the arrow and press Settin...

Reviews: