- 3 -
EN
&DXWLRQ
'RQRWRYHU¿OOWKHSRW7KH
scoring all around the upper pot
rim marks the limit for the max.
¿OOLQJKHLJKW
4. Switch the
Vario E
on at switch (A)
(Figure 4).
5. The most recently selected unit of tem-
SHUDWXUH&RU)DSSHDUVIRUDSSUR[
2 sec. on the display (F).
C = degrees Celsius (Figure 7a)
or
F= degrees Fahrenheit (Figure 7b)
6. The display (F) then shows the most
recently entered setpoint temperature
IRUWKHVHOHFWHGSRWIRUDSSUR[VHF
The selected pot is indicated by the LED
(C).
7. Finally, the display (F) shows the current
actual temperature in the most recently
selected pot. The selected pot is indi-
cated by the LED (C).
5.2 Specifying the Desired Tem-
perature Unit (°C or °F)
Note:
Please note that 230V units
have been preset to °C at the
factor, while 120V units are
preset to °F.
1. If your
Vario E
is switched on,
please turn it off at switch (A).
3UHVVDQGKROGNH\%DSSUR[VHF
(Figure 5) while simultaneously turning
the
Vario E
on at switch (A) (Figure 4).
3. The units of temperature, °C and °F are
DOWHUQDWHO\VKRZQIRUDSSUR[VHFRQ
the display (F)
(Figure 7a + 7b). Release key (B) when
the desired unit is displayed.
4. The most recently displayed unit of
temperature is saved.
5.3 Set-point
Temperature
Adjust-
ment
8VHVZLWFK%WRVHOHFWWKHGHVLUHGZD[
pot (Figure 5).
2. The LED (C) associated with the select-
ed pot goes on (red or green) (Figure 6).
5LJKWKDQGZD[SRW 5LJKWKDQG/('
&HQWUHZD[SRW &HQWUH/('
/HIWKDQGZD[SRW /HIWKDQG/('
'LVSOD\)¿UVWVKRZVWKHVHWSRLQWWHP
-
SHUDWXUHIRUDSSUR[VHFIROORZHGE\
the actual temperature.
4. Pressing either key (D +) or (E -) the
display (F) switches on to the currently
VSHFL¿HGVHWSRLQWWHPSHUDWXUH
(Figure 9 + 10).
5. Pressing keys (D +) or (E -) resets the
desired setpoint temperature (adjust-
ment range: 45-110°C or 113-230°F).
= Increase temperature
= Decrease temperature
By pressing the Minus-Key once again
at 45°C (113°F), the corresponding pot
will be switched off (the display shows
OFF). By pressing the plus-key, the pot
will be switched on again beginning at
45°C (113°F).
If an attempt is made to set a tem-
perature higher than 110°C (230°F),
WKHYDOXHRIZLOOÀDVKRQWKH
display (F).
$IWHUDSSUR[VHFWKHGLVSOD\)
automatically switches to the actual
temperature in the selected pot.
When the pre-set temperature on the
selected pot is reached, the indication
on the corresponding LED will turn from
UHGWRJUHHQ¿J7KHLQGLFDWLRQRQ
the LED (C) will always shortly turn on
red when re-adjusting temperature.
Summary of Contents for 14520000
Page 3: ...3 4 2 1b 1a A...
Page 4: ...5 6 7a 7b 8 9 10...