IMPORTANT SAFETY INFORMATION

 

           

WARNING

ARC FLASH AND ELECTRIC SHOCK HAZARD

Arc flash and electric shock hazard. Disconnect all electric 

power supplies, verify with a voltmeter that electric power is off 

and wear protective equipment per NFPA 70E before working 

within electric control enclosure. Failure to comply can cause 

serious injury or death.

Customer must provide earth ground to unit, per NEC, CEC and 

local codes, as applicable.

Before proceeding with installation, read all instructions, 

verifying that all the parts are included and check the nameplate 

to be sure the voltage matches available utility power.

The line side of the disconnect switch contains live high-voltage.

The only way to ensure that there is NO voltage inside the unit 

is to install and open a remote disconnect switch and verify that 

power is off with a volt meter. Refer to unit electrical schematic.
Follow all local codes.

 

RISK OF ELECTRIC SHOCK OR EQUIPMENT DAMAGE 

Whenever electrical wiring is connected, disconnected or 

changed, the power supply to the ERV and its controls must 

be disconnected. Lock and tag the disconnect switch or circuit 

breaker to prevent accidental reconnection of electric power.

RISK OF CONTACT WITH HIGH SPEED MOVING PARTS. 

Disconnect all local and remote power supplies, verify with 

a voltmeter that electric power is off and all fan blades have 

stopped rotating before working on the unit.

Do not operate this unit with any cabinet panels removed or 

prior to assembly of the modules

RISK OF DAMAGE TO ENTHALPIC CORES

Whenever working within the ERV cabinet, protect the enthalpic 

cores from accidental damage. The core media is subject to 

damage from dropped tools or other foreign objects. 

RISK OF CONTACT WITH HOT SURFACES

The blower motor and other electrical components are extremely 

hot during operation. Allow sufficient time for them to cool 

before working within the unit cabinet. Use extreme caution and 

wear protective gloves and arm protection when working on or 

near hot blower motors and electrical components.

This unit is intended for general ventilating only. Do not use to 

exhaust hazardous or explosive materials and vapors. Do not 

connect this equipment to range hoods, fume hoods or collection 

systems for toxics.

This unit is for ventilating finished structures only. It is not to 

be used until after all construction has been completed and 

construction debris and dust are cleaned from the Occupied 

Space. 

This equipment is to be installed by following Industry Best 

Practices and all applicable codes. Any damage to components, 

assemblies, subassemblies or the cabinet which is caused by 

improper installation practices will void the warranty.

NOTICE

NOTICE

NOTICE

CAUTION

CAUTION

CAUTION

CAUTION

Summary of Contents for LE10XIN

Page 1: ...INSTALLATION OPERATION MAINTENANCE MANUAL ENERGY RECOVERY VENTILATOR RENEWAIRE COM LE10XIN Model LE10XINV Shown also available as separate modules for field assembly...

Page 2: ...MOVING PARTS Disconnect all local and remote power supplies verify with a voltmeter that electric power is off and all fan blades have stopped rotating before working on the unit Do not operate this u...

Page 3: ...oped by the user to incorporate monthly and seasonal maintenance and include start up maintenance tasks as described in this manual If this unit is installed in an area where it may draw air from a ne...

Page 4: ...CONNECTIONS 24 7 0 CONTROL CONTRACTOR INFORMATION 24 7 1 24 VAC CLASS II POWER SUPPLY 24 7 2 MOTOR PROTECTION 25 7 2 1 Units Equipped with Motor Starters 25 7 2 2 Units With Variable Frequency Drives...

Page 5: ...LE10XINH Corner Weights 17 LE10XINV Corner Weights 17 Double Flange Duct Connection 20 E Box Main Disconnect Switch 21 E Box with Knockouts on Bottom 21 E Box Low Voltage Terminal Strip 21 24 VAC Pow...

Page 6: ...Standard F Fused Unit Control Enhancements Digit 21 T Transformer with Isolation Relay Standard 1 Enhanced Controls 2 Premium Controls 3 Enhanced Controls with BACNET License 4 Premium Controls with B...

Page 7: ...60 Single 14 7 14 33 1 40 9 38 8 48 40 2 45 3 0 208 230 460 575 60 60 60 Three Three Three 9 38 8 48 4 24 3 3 21 1 9 5 7 4 25 15 15 9 38 8 48 4 24 3 3 23 2 10 5 8 2 25 15 15 5 0 208 230 460 575 60 60...

Page 8: ...6 E Box Minimum Service Area 79 7 8 Minimum Blower Service Area Typ 111 Minimum Service Area Door Swing Door Swing Door Swing Door Swing RA FA OA EA TOP VIEW RIGHT VIEW FA OA RA EA Model LE10XINH Draw...

Page 9: ...6 670 1 9 740 2 1 810 2 5 880 2 8 940 3 1 1000 3 5 1060 3 9 1120 5500 3 HP LOW SPEED 1 6 640 1 9 710 2 2 770 2 5 840 2 8 900 3 1 960 3 5 1020 3 8 1080 4 2 1130 6000 2 0 690 2 2 750 2 5 810 2 8 870 3...

Page 10: ...m Service Area 79 7 8 Minimum Blower Service Area 111 Minimum Service Area 36 E Box Minimum Service Area Door Swing Door Swing Door Swing Door Swing RA FA EA OA TOP VIEW LEFT VIEW RIGHT VIEW RA FA OA...

Page 11: ...t are to be assembled in the field The customer may optionally order the modules to be assembled into one unit in the factory See Digit 23 of the Config uration Code RA Room Air into unit OA Outside A...

Page 12: ...ternate Duct Connections OA EA RA FA RA Room Air into unit OA Outside Air into unit FA Fresh Air to inside EA Exhaust Air to outside LE INH RA FA OA EA Duct Connections as Labeled NOTE Airstreams alwa...

Page 13: ...or spring vibration isolators depending on the option selected at time of order See Digit 10 of the Configuration Code Dampers are specified by the customer at time of order Order options are None Da...

Page 14: ...tivate the unit at user selected times When optional VFDs are ordered and there is no microprocessor controller the optional CO2 sensor or the optional IAQ sensor may be wired directly to the VFD prod...

Page 15: ...rectly to the ERV low voltage terminal strip When wired to the ERV low voltage terminal strip each device functions as an ON OFF switch for the ERV but they will not modulate the ERV All of the option...

Page 16: ...that are equipped with a VFD See the description in Section 2 7 Controls It uses 0 84 VA 2 8 4 Motion Occupancy Control 2 8 5 Smoke Detector A motion occupancy sensor is available as an optional cont...

Page 17: ...WITHOUT NOTICE RenewAire LLC Do not scale drawing LE10X INH_CORNER_WEIGHTS_MAY18 dwg LE10X INH Corner Weights Sheet 1 of 4 73 5 Lifting Lug LR RR LF RF 194 5 Lifting Lug BASIC UNIT WEIGHTS lbs Motors...

Page 18: ...Corner Weights in this manual 4 1 1 Unit Dimensions and Weight 4 1 2 Shipping Dimensions and Weight Upon delivery of the ERV inspect it carefully for shipping damage and completeness Verify the pres e...

Page 19: ...tion specified by others There are a number of situations that may demand relocation The outside air intake must be at least 10 away from exhausts such as dryer vents chimneys furnace and water heater...

Page 20: ...duct The ducts connecting to the outlets should be straight for a sufficient distance with gradual transitions to the final duct size These guidelines are consistent with SMACNA recommended duct layo...

Page 21: ...o be sure the voltage matches available utility power The line side of the disconnect switch contains live high voltage The only way to ensure that there is NO voltage inside the unit is to install an...

Page 22: ...ER BETWEEN TERMINALS 2 3 FACTORY SETTINGS Overload Relay Trip Settings Motor Nameplate FLA Overload Relay Mode Settings Manual position KEY FA Fresh Outside Air Blower EA Exhaust Air Blower FACTORY WI...

Page 23: ...ED JUMPER BETWEEN TERMINALS 2 3 FACTORY SETTINGS Overload Relay Trip Settings Motor Nameplate FLA Overload Relay Mode Settings Manual position KEY FA Fresh Outside Air Blower EA Exhaust Air Blower FAC...

Page 24: ...in the unit s E Box The unit s power supply system includes isolation relays with contact ratings as low as 50 mA 1 2 VA It is also possible to operate the isolation relays with 24 VAC power from an e...

Page 25: ...BMS such as BACnet unless the unit is equipped with microprocessor controls The unit can be controlled by powered or non powered contacts operated by any kind of control system Units that are equippe...

Page 26: ...OTE Some units are equipped with only one VFD which controls a single motor The second motor without a VFD is then protected by an overload relay as described before External control wiring is to be t...

Page 27: ...ion relay for the RA EA blower Supply only 24 VAC not VDC from a Class II power source Use the schematic below if external control is to be applied using 24 VAC from the ERV power supply External cont...

Page 28: ...Powered Relay Contacts Control with 2 ON Signals External Power Basic Sequence of Operation SOO Operating sequences are different depending on whether the unit is Controlled for simultaneous blower o...

Page 29: ...r through the blower s VFD If that blower is controlled by a motor starter it starts immediately Variable Frequency Drives VFDs When one or both of the blowers are factory provided with VFDs the respo...

Page 30: ...the foam gasketing positioned toward the filter One filter retainer is used for each set of five filters in LE10X units positioned as shown in the installation instructions Proper installation of foa...

Page 31: ...mpers should be tested at start up to verify that the dampers will open fully 9 2 1 Motor Starter Units Units without dampers both motors should begin running immediately Units with dampers dampers sh...

Page 32: ...operation Tighten all electrical connections paying special attention to VFD wiring if present Readjust the tension on motor drive belts Check the air filters as part of the normal monthly maintenanc...

Page 33: ...owest tension at which the belts will not slip under peak load operation For initial tensioning set the belt deflection at 1 64 inch for each inch of belt span measured half way between sheave centers...

Page 34: ...he load on the bearing Grease is basically a carrier for specific oils that are needed for each application Greases are made with different thickeners and these thickeners are often incompatible with...

Page 35: ...nd stop when the first sign of grease seepage from the bearing s seals is observed Leave a small amount of grease on the zerk as a protective coating In all cases Industry Best Practices should be obs...

Page 36: ...pic cores for cleaning remove the air filters To clean enthalpic cores all exposed surfaces must be vacuumed with an attachment having long soft bristles The greatest buildup of dirt and dust will nor...

Page 37: ...IN ERV 37 1 800 627 4499 INSTALLATION OPERATION AND MAINTENANCE MANUAL RENEWAIRE COM MAINTENANCE 10 8 SERVICE PARTS www renewaire com 800 627 4499 support renewaire com LE10XINH and LE10XINV Service P...

Page 38: ...lace significant weight on the plenum dividers They are not intended to be load bearing The fan and fan motor are part of an assembly that is mounted on a sled which is then installed in the ERV on vi...

Page 39: ...raw ten filters at once See image below When installing the filter spacers the foam strip is to be placed against the filter Note that when new filters are installed the filter spacers may tend to fal...

Page 40: ...e The differential static pressures DSP can be measured using the installed pressure test ports shown above Airstream pressure readings are to be taken across the cores by testing at diagonally locate...

Page 41: ...n the set screws on both adjustable flanges IN HALF TURN INCREMENTS turn the adjustable flanges in or out the same number of turns Tighten the set screws on the adjustable flanges making certain that...

Page 42: ...EWAIRE COM INSTALLATION OPERATION AND MAINTENANCE MANUAL 1 800 627 4499 42 MAINTENANCE 11 9 MAINTENANCE RECORDS FILTERS REPLACED DATE CORES CLEANED DATE AIR FILTER REPLACEMENT RECORD ENTHALPIC CORES C...

Page 43: ...REQUIREMENTS REAR BEARING LUBE REQUIREMENTS MOTOR TYPE REQUIRED LUBRICANT from motor manufacturer s website FRONT BEARING LUBE REQUIREMENTS REAR BEARING LUBE REQUIREMENTS LUBRICATION PERFORMED DATE L...

Page 44: ...rt workmanship and Quick Response Manufacturing QRM As the pioneer of static plate core technology in North America RenewAire is the largest ERV producer in the USA We re committed to sustainable manu...

Reviews: