Page 8

HE3XINV P3 Wiring Schematics with Independent Blower Control

24VAC

24VAC

MOTOR

(OA)

MOTOR

(EA)

C

1

2

3

4

5

POWER SUPPLY

3 PHASE 60Hz

SEE UNIT RATING LABEL 

FOR VOLTAGE, MCA 

AND MOPD

Call for OA Blower Operation.

C

OPTIONS INSTALLED: INDEPENDENT BLOWER CONTROL

GND

Call for EA Blower Operation.

RELAY

1

2

3

4

5

Call for OA Blower Operation.

Call for EA Blower Operation.

OUT 24VAC 

Class II

RELAY

TRANSFORMER AND  CIRCUIT

 BREAKER

DISCONNECT 

SWITCH

MOTOR STARTER

MOTOR STARTER

FUSE

(IF INSTALLED AT FACTORY)

24VAC

JUMPER PROVIDED

FACTORY SETTINGS:

  Overload Relay Trip Settings = Motor Nameplate FLA

  Overload Relay Mode Settings:"Manual" position

KEY:

  "OA" = Outside Air Blower

  "EA" = Exhaust Air Blower

FACTORY WIRING HIGH-VOLTAGE

FACTORY WIRING 24VAC

FIELD WIRING

"UNIT CONTROL USING CLASS II 24VACPOWER PROVIDED BY THIS UNIT"

 

24VAC POWER AVAILABLE AT TERMINALS 1 & 2

 

INSTALL PROVIDED JUMPER BETWEEN TERMINALS 2 & 3

"UNIT CONTROL USING CLASS II 24VAC POWER FROM ANOTHER POWER SOURCE"

 

24VAC POWER AVAILABLE AT TERMINALS 1 & 2

 

DO NOT INSTALL JUMPER BETWEEN TERMINALS 2 & 3

Summary of Contents for HE3XINV

Page 1: ...xhausting of gases through the flue chimney of fuel burning equipment that might be installed in the area affected by this equipment If this unit is exhausting air from a space in which chimney vented...

Page 2: ...to inside EA Exhaust Air to outside NOTE Airstreams always cross in the energy exchange core Duct Connections as Labeled Alternate Duct Connections RA EA FA OA RA EA FA OA The fresh air inlet should...

Page 3: ...ive or negative pressure in the building is desired RenewAire heat recovery ventilators can generally operate with a flow imbalance of up to 20 without appreciable loss in heat recovery efficiency How...

Page 4: ...IN INDOOR 1 5 MODEL HE 3X 20 16 17 UNUSED IN HE 3X MODELS 24 L LISTED N NON LISTED OPTION 4 OTHERS T TR TRANSFORMER WITH ISOLATION RELAY NONE W WHITE PAINT C CUSTOM PAINT X CUSTOM UNIT 1 2 3 4 5 6 7 8...

Page 5: ...ns and manometers These also can be used to determine when filters should be cleaned or changed Use Static Taps in Doors to Measure Airflow Rates See Cross Core Static Drop in MEASURING AIRFLOW table...

Page 6: ...locate pressure ports To read SCFM of Fresh Air FA install the high pressure side of your measuring device to the Outside Air OA port and the low pressure side to the Fresh Air FA port To read SCFM of...

Page 7: ...DISCONNECT SWITCH MOTOR STARTER MOTOR STARTER FUSE IF INSTALLED AT FACTORY JUMPER PROVIDED MOTOR EA FACTORY SETTINGS Overload Relay Trip Settings Motor Nameplate FLA Overload Relay Mode Settings Manu...

Page 8: ...Operation Call for EA Blower Operation OUT 24VAC Class II RELAY TRANSFORMER AND CIRCUIT BREAKER DISCONNECT SWITCH MOTOR STARTER MOTOR STARTER FUSE IF INSTALLED AT FACTORY 24VAC JUMPER PROVIDED FACTOR...

Page 9: ...the control terminals of this unit 5 Unit is not equipped to receive analog signals such as 1 10vdc or 4 20mA 6 Unit is not equipped to communicate directly with Building Management Systems such as B...

Page 10: ...Connect Terminals 2 3 Connect Switch between Terminals 1 4 UNIT INTERNAL CONTROL WIRING SIMPLIFIED A SWITCH OR NON POWERED CONTROL USING UNIT S 24VAC POWER SUPPLY UNIT INTERNAL CONTROL WIRING SIMPLIFI...

Page 11: ...34772_006 HE3XINVMan_Jan12 indd Revised 01 2012 www renewaire com Page 11 HE3XINV Replacement Parts A CORES B FILTERS C DOOR D DRAW LATCH E DISCONNECT SWITCH F TRANSFORMER G ISOLATION RELAY H OVERLOAD...

Page 12: ...Blowers every time you change the filters Confirm bearings are still secure to blower shaft It should not be possible to move the blower shaft back and forth along its length Confirm blower wheel is n...