M306NKT3-RPD-E User’s Manual
2. Setup
REJ10J0326-0400 Rev.4.00 Sep. 01, 2006
Page 32 of 104
2.8.1 Connecting to a 100-pin LCC socket
Figure 2.10 shows how to connect a 100-pin LCC socket (IC61-1004-051 of Yamaichi Electronics Co., Ltd.) on the user
system to the M30800T-PTC (included).
(1) Attach the CN2 side of the M30800T-PTC to the CN2 side of the package converter board connected to the emulation pod
probe.
(2) Attach the M30800T-PTC to the 100-pin LCC socket.
100 - pin LCC socket
CN 2 side
(1)
No. 1 pin
(2)
M30800 T-PTC
User system
Package converter board
Tip of emulation pod probe
Figure 2.10 Connecting to a 100-pin LCC socket
CAUTION
Note on Connecting the User System:
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulation
pod.
The connectors of the M30800T-PTC are guaranteed for only 50 insertion/removal iterations.
The connectors of the IC61-1004-051 are guaranteed for only 20 insertion/removal iterations.
For purchasing the IC61-1004-051 or for technical information, contact Yamaichi Electronics Co., Ltd.