Summary of Contents for HS8000EST02H

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...tc Accordingly although Hitachi Hitachi Ltd Hitachi Semiconductors and other Hitachi brand names are mentioned in the document these names have in fact all been changed to Renesas Technology Corp Than...

Page 4: ...SH7410 E8000 Emulator Diagnostic Program Manual User s Manual...

Page 5: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 6: ...emulator product is not authorized for use in MEDICAL atomic energy aeronautical or space technology applications without consent of the appropriate officer of a Hitachi sales company Such use include...

Page 7: ...y purchases the emulator product from you Hitachi is not liable for any claim made by a third party or made by you for a third party DISCLAIMER HITACHI MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED OR...

Page 8: ...t may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Hitachi s prior written consent Other Important Things to Keep in Mind 1 Circuitry an...

Page 9: ...which if not avoided will result in DEATH or SERIOUS INJURY to you or other people WARNING indicates a potentially hazardous situation which if not avoided could result in DEATH or SERIOUS INJURY to y...

Page 10: ...mulator product has a DC power supply Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the emulator product and the use...

Page 11: ...sult in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST WARNING Place the emulator station and EV chip board so t...

Page 12: ...ing the E8000 emulator for Hitachi s original microcomputer SH7410 The diagnostic program automatically checks whether the E8000 emulator is operating correctly Read this manual and understand it befo...

Page 13: ...peration Flowchart 8 3 4 Data Output to the Printer 9 Section 4 Procedures 11 4 1 Installation Procedure 12 4 2 Operation Procedure 14 Section 5 Error Handling 23 Section 6 Testing Circuits and Connec...

Page 14: ...not capable of finding all failures possible to occur in the E8000 emulator 2 If execution results of the diagnostic program indicate a failure in the E8000 emulator inform a Hitachi sales agency of t...

Page 15: ...control board HS7410EDD82H Always necessary Trace board HS8000PWB82H Always necessary PC I F board HS8000PWB85H Always necessary LAN board HS7000ELN01H or HS7000ELN02H Depends on user system configur...

Page 16: ...E8000 station System floppy disk Device control board Trace cables coaxial cables EV chip board EV chip installed E8000 ONLY E8000 EVCHIP Printer Serial interface cable RS232C Bidirectional parallel i...

Page 17: ...ot be obtained when the E8000 emulator is still connected to the user system Independent E8000 Emulator System Test E8000 ONLY The system configuration shown in figure 2 1 is used for testing the inde...

Page 18: ...d If ERROR CONTINUE is specified the test resumes execution after an error content display When initiating the diagnostic program select whether to execute the following tests Operation tests Serial i...

Page 19: ...Control board register test O O TEST11 IDR READ E8000 hardware configuration check O O TEST12 DIP SWITCH TEST Control board DIP switch test TEST13 TRACE REG TEST Trace board register test O O TEST14 T...

Page 20: ...rein the error occurred If N is entered displays the following message Continue Y N If Y is entered quits testing the test item wherein the error occurred and goes on to the next test item If N is ent...

Page 21: ...8000 EVCHIP E8000 EVCHIP FIXED USER The user cannot perform this test to Figure 3 1 Diagnostic Program Operation Flowchart Note TEST06 is executed when the optional LAN board test is specified TEST07...

Page 22: ...EMORY TOOL L SET LAN PARAMETER T START DIAGNOSTIC TEST S F L T a TM LOG RET a S F L T t RET b Diagnostic program execution CTRL C c q RET d E8000 MONITOR HS8000EST02SR Vn m Copyright C Hitachi Ltd 199...

Page 23: ...er the following command to return to the monitor command input wait state q RET e Enter the following command in the monitor command input wait state to terminate data output to the file RET f Printi...

Page 24: ...vices or will result in PERSONAL INJURY Notes 1 To execute the diagnostic program DIAG SYS must be installed in flash memory according to the instructions in the SH7410 E8000 Emulator User s Manual HS...

Page 25: ...ARAMETER T START DIAGNOSTIC TEST S F L T _ 4 Enter F RET to initiate the flash memory management tool The emulator displays prompt FM and waits for a flash memory management tool command S F L T F RET...

Page 26: ...AD DIAGNOSTIC FILE OK Y N Y RET INPUT COMMAND B A DIAG SYS RET COMPLETED 12 Enter DIR RET to check whether the necessary files have been loaded FM DIR RET FILE ID STATUS SYS OK CONF OK LAN NO FIRM OK...

Page 27: ...following power supplies Personal computer E8000 emulator For other components supply an appropriate voltage according to the user system configuration 3 Start up the host interface software IPW on th...

Page 28: ...ns should be entered by the user Both uppercase and lowercase letters are acceptable 2 RET RETURN key 4 Load the diagnostic program according to the following procedure Loading Diagnostic Program STAR...

Page 29: ...rror occurs c 1 Independent E8000 emulator system test 2 E8000 emulator device control board and EV chip board test 3 E8000 emulator system test at shipment cannot be used d Enter Y to execute the ser...

Page 30: ...hout operator interventions If no error occurs the following messages are displayed TEST07 P1284 I F TEST COUNT 001 FIFO R W TEST OK PARALLEL INTERRUPT TEST OK 8 For executing the serial interface tes...

Page 31: ...ic program execution Perform the following operations while executing the operation tests Operation Procedures for TEST12 DIP SWITCH TEST 1 Enter Y to the following message at diagnostic program initi...

Page 32: ...DIP switches as shown in figure 4 3 3 enter Y 10 If no error occurs the following message is displayed TEST OK Note RET RETURN key 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 DIP switch setting 5555 2 DIP switc...

Page 33: ...CONNECTOR EXIST Y N N P1284 LOOP CONNECTOR EXIST Y N N OPTION LAN BOARD EXIST Y N N START Y N Y TEST01 FLASH MEMORY READ TEST COUNT 001 1 MONITOR SUM CHECK OK 2 SYSTEM SUM CHECK OK 3 EVCHIP FIRM SUM C...

Page 34: ...NT 001 1 EBOX ID CODE OK 2 EBOX ID CHECK OK 3 SHARED RAM TEST OK 4 WORK RAM TEST OK 5 ULSR TEST OK 6 MAPR R W TEST OK TEST17 ERAM WINDOW TEST COUNT 001 1 ERAM WINDOW TEST OK 2 ERAM WP TEST OK TEST18 E...

Page 35: ...EST OK 7 INRAM TRACE TEST OK TEST24 ERAM TIME MEASURE TEST COUNT 001 1 SUBROUTINE TIME MEASURE TEST1 OK 2 SUBROUTINE TIME MEASURE TEST2 OK 3 SUBROUTINE TIME MEASURE TEST3 OK 4 TIME STUMP TEST OK TEST2...

Page 36: ...23 Section 5 Error Handling If an error occurs provide a Hitachi sales agency with a detailed description of the problem...

Page 37: ...SELECT P SELECTIN N ACK N STROBE N PERROR P INIT N 1 17 2 16 3 15 5 14 Figure 6 1 Testing Circuit for P1284 Loop Back Test 6 2 Testing Circuit for SERIAL I F TEST TEST08 Connect the testing circuit in...

Page 38: ...emulator Table 6 1 lists the signal name of each pin 1 2 3 4 5 6 7 8 9 SERIAL Figure 6 3 Pin Locations in E8000 Emulator Serial Interface Connector Table 6 1 Pin Signal Names in E8000 Emulator Serial...

Page 39: ...31 30 29 28 27 26 25 24 23 22 21 20 19 Figure 6 4 Pin Locations in E8000 Emulator Bidirectional Parallel Interface Connector Table 6 2 Pin Signal Names in E8000 Emulator Bidirectional Parallel Interfa...