HD74LVC1G66
Rev.3.00 Jul. 01, 2004 page 4 of 10
Switching Characteristics
V
CC
= 1.8 ± 0.15 V
Ta = –40 to 85°C
Item
Symbol
Min
Max
Unit
Test Conditions
FROM
(Input)
TO
(Output)
Propagation delay time*
1
t
PLH
t
PHL
2.0
C
L
= 30 pF, R
L
= 1.0 k
Ω
INOUT or
OUTIN
OUTIN or
INOUT
Enable time
t
ZH
t
ZL
2.5
12.0
C
L
= 30 pF, R
L
= 1.0 k
Ω
CONT
INOUT or
OUTIN
Disable time
t
HZ
t
LZ
2.2
10.0
ns
C
L
= 30 pF, R
L
= 1.0 k
Ω
CONT
INOUT or
OUTIN
V
CC
= 2.5 ± 0.2 V
Ta = –40 to 85°C
Item
Symbol
Min
Max
Unit
Test Conditions
FROM
(Input)
TO
(Output)
Propagation delay time*
1
t
PLH
t
PHL
1.2
C
L
= 30 pF, R
L
= 500
Ω
INOUT or
OUTIN
OUTIN or
INOUT
Enable time
t
ZH
t
ZL
1.9
6.5
C
L
= 30 pF, R
L
= 500
Ω
CONT
INOUT or
OUTIN
Disable time
t
HZ
t
LZ
1.4
6.9
ns
C
L
= 30 pF, R
L
= 500
Ω
CONT
INOUT or
OUTIN
V
CC
= 3.3 ± 0.3 V
Ta = –40 to 85°C
Item
Symbol
Min
Max
Unit
Test Conditions
FROM
(Input)
TO
(Output)
Propagation delay time*
1
t
PLH
t
PHL
0.8
C
L
= 50 pF, R
L
= 500
Ω
INOUT or
OUTIN
OUTIN or
INOUT
Enable time
t
ZH
t
ZL
1.8
5.0
C
L
= 50 pF, R
L
= 500
Ω
CONT
INOUT or
OUTIN
Disable time
t
HZ
t
LZ
2.0
6.5
ns
C
L
= 50 pF, R
L
= 500
Ω
CONT
INOUT or
OUTIN
V
CC
= 5.0 ± 0.5 V
Ta = –40 to 85°C
Item
Symbol
Min
Max
Unit
Test Conditions
FROM
(Input)
TO
(Output)
Propagation delay time*
1
t
PLH
t
PHL
0.6
C
L
= 50 pF, R
L
= 500
Ω
INOUT or
OUTIN
OUTIN or
INOUT
Enable time
t
ZH
t
ZL
1.5
4.2
C
L
= 50 pF, R
L
= 500
Ω
CONT
INOUT or
OUTIN
Disable time
t
HZ
t
LZ
1.4
5.0
ns
C
L
= 50 pF, R
L
= 500
Ω
CONT
INOUT or
OUTIN
Note:
1. The propagation delay is calculated RC time constant of typical on-state resistance of the switch and the