HD74LVC1G66
Rev.3.00 Jul. 01, 2004 page 3 of 10
Recommended Operating Conditions
Item
Symbol
Min
Max
Unit
Conditions
Supply voltage range
V
CC
1.65
5.5
V
Control Input voltage range
V
I
0
5.5
V
Input/Output voltage range
V
I/O
0
V
CC
V
0
20
V
CC
= 1.65 to 1.95 V,
2.3 to 2.7 V
0
10
V
CC
= 3.0 to 3.6 V
Input transition rise or fall rate
∆
t /
∆
v
0
10
ns / V
V
CC
= 4.5 to 5.5 V
Operating free-air temperature
T
a
–40
85
°C
Note:
Unused or floating inputs must be held high or low.
Electrical Characteristics
Ta = –40 to 85°C
Item
Symbol
V
CC
(V)
Min
Typ
Max
Unit
Test condition
1.65 to 1.95
V
CC
×
0.65
—
—
2.3 to 2.7
V
CC
×
0.7
—
—
3.0 to 3.6
V
CC
×
0.7
—
—
V
IH
4.5 to 5.5
V
CC
×
0.7
—
—
1.65 to 1.95
—
—
V
CC
×
0.35
2.3 to 2.7
—
—
V
CC
×
0.3
3.0 to 3.6
—
—
V
CC
×
0.3
Input voltage
V
IL
4.5 to 5.5
—
—
V
CC
×
0.3
V
1.65
—
13
30
I
S
= 4 mA
2.3
—
9
20
I
S
= 8 mA
3.0
—
7.5
15
I
S
= 24 mA
On–state switch
resistance
R
ON
4.5
—
5.5
10
I
S
= 32 mA
V
I
=V
CC
or GND
1.65
—
74.5
120
I
S
= 4 mA
2.3
—
20
30
I
S
= 8 mA
3.0
—
11.5
20
I
S
= 24 mA
Peak on resistance
R
ON
(P)
4.5
—
7.5
15
Ω
I
S
= 32 mA
V
I
=V
CC
to GND
—
—
±1.0
Off-state switch
leakage current
I
S (OFF)
5.5
—
—
±0.1*
1
µ
A
V
I
= V
CC
and V
O
= GND or
V
I
= GND and V
O
= V
CC
,
V
C
= V
IL
—
—
±1.0
On-state switch
leakage current
I
S (ON)
5.5
—
—
±0.1*
1
µ
A
V
I
= V
CC
or GND, V
C
= V
IH
V
O
= Open
—
—
±1.0
Control input
current
I
IN
5.5
—
—
±0.1*
1
µ
A
V
IN
= V
CC
or GND
—
—
10
I
CC
5.5
—
—
1.0*
1
µ
A
V
IN
= V
CC
or GND
Quiescent
supply current
∆
I
CC
5.5
—
—
500
µ
A
V
C
= V
CC
–0.6 V
Control input
capacitance
C
IC
5.0
—
3.0
—
pF
C
I/O(OFF)
5.0
—
6.0
—
Switch terminal
capacitance
C
I/O(ON)
5.0
—
13
—
pF
Note:
1. Ta = 25°C