2.3 

Connecting the User System Interface Board to the Evaluation Chip 
Board 

WARNING

 

   

Observe the precautions listed below.  Failure to do so  

  will result in a FIRE HAZARD and will damage the user  
  system and the emulator product or will result in  
  PERSONAL INJURY.  The USER PROGRAM will be  
  LOST.   
  1.   Always switch OFF the user system and the emulator 
   

product before the USER SYSTEM INTERFACE BOARD  

   

is connected or removed.  Before connecting the two, 

   

make sure that the pin 1 positions on both sides are  

   

correctly aligned.  

  2.  The user system interface board must be used with the  
   

emulator for which it was designed.   

1.  Make sure the user system and emulator are turned off. 

2.  Align the connectors on the user system interface board with those on the evaluation chip 

board by matching the numbers on the connectors (figure 5). 

3.  Adjust the height of the spacers of the evaluation chip board to accommodate the user system. 

Summary of Contents for H8SX/1663 E6000H FP-144L

Page 1: ...E6000H FP 144L User System Interface Board HS1664ECH61H User s Manual Renesas Microcomputer Development Environment System H8SX Family H8SX 1600 Series HS1664ECH61HE REJ10J1395 0100 Revision Date Jun...

Page 2: ......

Page 3: ...fore making a final decision on the applicability of the information and products Renesas Technology Corp assumes no responsibility for any damage liability or other loss resulting from the informatio...

Page 4: ......

Page 5: ...er system interface board must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy o...

Page 6: ...om you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HE...

Page 7: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas prior written consent Other Important Things to Keep in Mind 1 Circuitry and...

Page 8: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Page 9: ...n PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000H emulator...

Page 10: ...face board that connects a user system for the H8SX 1663 H8SX 1664 FP 144L package to the H8SX 1650 E6000H emulator HS1650EPH60H Emulation of the H8SX 1663 group is only possible when this user system...

Page 11: ...aluation Chip Board 8 2 3 Connecting the User System Interface Board to the Evaluation Chip Board 9 2 4 Recommended Dimensions for the User System Mounting Pad Footprint 11 2 5 Dimensions of the Evalu...

Page 12: ...FP 144L package Please make sure you have all of these components after you have unpacked the box Evaluation chip board Spacer User system interface board User system IC socket Screws M2 10 mm for fa...

Page 13: ...ket 1 For the FP 144L package to be mounted on the user system 3 Socket cover 1 For installing an FP 144L packaged MCU 4 Screw M2 x 10 mm 4 For fastening the board 5 Screw M2 x 6 mm 4 For installing a...

Page 14: ...do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST CAUTION 1 Do not connect a 5 V signal to an...

Page 15: ...he IC socket apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket and fasten it to the user system Use the guide pins provided with the product to determine whe...

Page 16: ...illets Use slightly more solder than with the MCU 2 1 3 Inserting the IC Socket Connector CAUTION Check the location of pin 1 before inserting After checking the location of pin 1 on the user system i...

Page 17: ...y be caused by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if neces...

Page 18: ...em interface board User system Pin 1 Screws M2 10 mm for fastening the board IC socket NQPACK144SD manufactured by Tokyo Eletech Corporation Figure 3 Connecting the User System Interface Board to the...

Page 19: ...ard to the user system be careful not to apply load to the user system Exchange the spacers 2 6MP 10 mm of the evaluation chip board with the spacers 2 6MP 25 mm provided with the user system interfac...

Page 20: ...before the USER SYSTEM INTERFACE BOARD is connected or removed Before connecting the two make sure that the pin 1 positions on both sides are correctly aligned 2 The user system interface board must b...

Page 21: ...or No UCN1 UCN1 UCN2 UCN2 User system interface board Evaluation Chip Board Connector No Board Connector No Evaluation chip board Figure 5 Connecting the User System Interface Board to the Evaluation...

Page 22: ...with the IC socket for an FP 144L package NQPACK144SD manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the mounting pad for the syst...

Page 23: ...of the evaluation chip board and the user system interface board are shown in figure 7 Unit mm Tolerance 0 5 mm 140 0 Evaluation chip board User system interface board 102 5 16 0 118 5 100 0 84 5 69...

Page 24: ...nterface board has been connected to the user system are shown in figure 8 Unit mm Tolerance 1 0 mm 32 9 13 3 54 9 User system Evaluation chip board IC socket NQPACK144SD manufactured by Tokyo Eletech...

Page 25: ...HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST CAUTION When this emulator is used without connecting to the user syste...

Page 26: ...15 P1 SW1 USER ON USER OFF Figure 9 SW1 Jumper Socket Spacer 2 6MQ x 13 mm Figure 10 Attaching Spacers...

Page 27: ...D USD USD USD Power supply circuit EPM7128 1 k Vcc 47 k MD3 EPM7128 Monitoring circuit Figure 11 User System Interface Circuit 1 Note The power supply circuit shown above is turned on off by the setti...

Page 28: ...3 P27 P23 P27 SN74CB3Q3306A SN74CB3Q3306A MCU User system Figure 12 User System Interface Circuit 2 MCU User system Sub MCU P14 P14 SN74CB3Q3306A TXD SN74CB3Q3306A Figure 13 User System Interface Circ...

Page 29: ...18 MCU VHC244 UHC14 _RES Vcc User system EPM7128 EPM7128 _RES 47 k Figure 14 User System Interface Circuit 4...

Page 30: ...ds of clock sources as the MCU clock For details refer to the H8SX 1650 E6000H Emulator User s Manual HS1650EPH60HE To use the emulator internal clock Select the clock in the emulator by the CLOCK com...

Page 31: ...aluation chip board Install the crystal oscillator into the crystal oscillator terminals on the evaluation chip board Evaluation chip board Crystal oscillator terminals Crystal oscillator Enlarged vie...

Page 32: ...of the pad for the MCU 4 This user system interface board is specifically designed for the HS1650EPH60H emulator Do not use this board with any other emulator 5 When power is not being supplied to the...

Page 33: ...USB 9 To connect the emulator to the user system ensure that the SW1 jumper pin is inserted to USER ON While SW1 jumper pin is inserted to USER ON the emulator does not supply power to DrVCC which is...

Page 34: ...e port pin state cannot be read from the port register 3 The user system interface board does not support subclock operation Thus the following function and register cannot be used 32k timer Subclock...

Page 35: ...s Manual Publication Date Rev 1 00 June 28 2006 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Customer Support Department Global Strategic Communication Div Renesas Solu...

Page 36: ...Renesas Technology Hong Kong Ltd 7th Floor North Tower World Finance Centre Harbour City 1 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2265 6688 Fax 852 2730 6071 Renesas Technology Taiwan Co L...

Page 37: ...H8SX 1663 Group E6000H FP 144L User System Interface Board HS1664ECH61H User s Manual...

Reviews: