Renesas H8S/2633 User Manual Download Page 4

II 

 

 

LIMITED WARRANTY 

       Renesas warrants its user system interface cables to be manufactured  
  in accordance with published specifications and free from defects in  
  material and/or workmanship. Renesas will repair or replace any  
  user system interface cables determined to be defective in material  
  and/or workmanship. User system interface cables are wearing parts  
  which Renesas will not repair or replace if damaged and/or worn  
  through use. The foregoing shall constitute the sole remedy for any  
  breach of Renesas’ warranty. This warranty extends only to you, the  
  original Purchaser. It is not transferable to anyone who subsequently  
  purchases the user system interface cable from you. Renesas is not 
  liable for any claim made by a third party or made by you for a third 
 party. 

DISCLAIMER 

       RENESAS MAKES NO WARRANTIES, EITHER EXPRESS OR  
  IMPLIED, ORAL OR WRITTEN, EXCEPT AS PROVIDED  
  HEREIN, INCLUDING WITHOUT LIMITATION THEREOF,  
  WARRANTIES AS TO MARKETABILITY, MERCHANTABILITY,  
  FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR  
  AGAINST INFRINGEMENT OF ANY PATENT. IN NO EVENT  
  SHALL RENESAS BE LIABLE FOR ANY DIRECT, INCIDENTAL  
  OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR  
  LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE  
  USER SYSTEM INTERFACE CABLE, THE USE OF ANY USER  
  SYSTEM INTERFACE CABLE, OR ITS DOCUMENTATION,  
  EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.   
  EXCEPT AS EXPRESSLY STATED OTHERWISE IN THIS  
  WARRANTY, THIS USER SYSTEM INTERFACE CABLE IS SOLD  
  "AS IS ", AND YOU MUST ASSUME ALL RISK FOR THE USE  
  AND RESULTS OBTAINED FROM THE USER SYSTEM  
 INTERFACE CABLE. 

Summary of Contents for H8S/2633

Page 1: ...2004 1 29 H8S 2633 Group QFP 128 User System Interface Cable HS2633ECH61H User s Manual Renesas Microcomputer Development Environment System Rev 5 00...

Page 2: ...described here may contain technical inaccuracies or typographical errors Renesas Technology Corp assumes no responsibility for any damage liability or other loss rising from these inaccuracies or err...

Page 3: ...system interface cable must only be used for the above purpose Improvement Policy Renesas Technology Corp including its subsidiaries hereafter collectively referred to as Renesas pursues a policy of c...

Page 4: ...om you Renesas is not liable for any claim made by a third party or made by you for a third party DISCLAIMER RENESAS MAKES NO WARRANTIES EITHER EXPRESS OR IMPLIED ORAL OR WRITTEN EXCEPT AS PROVIDED HE...

Page 5: ...rt may be reproduced or duplicated in any form in hard copy or machine readable form by any means available without Renesas prior written consent Other Important Things to Keep in Mind 1 Circuitry and...

Page 6: ...low this symbol to avoid possible injury or death DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a pote...

Page 7: ...in PERSONAL INJURY The USER PROGRAM will be LOST 1 Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance 2 Always switch OFF the E6000 emulator...

Page 8: ...s original microcomputer H8S 2633 group The HS2633ECH61H is a user system interface cable that connects an H8S 2633 group E6000 emulator HS2633EPI61H hereinafter referred to as the emulator to the IC...

Page 9: ...C Socket 6 2 2 2 Soldering IC Socket 7 2 2 3 Inserting Cable Head 7 2 2 4 Fastening Cable Head 8 2 2 5 Fastening Cable Body 10 2 3 Recommended Dimensions for User System Mount Pad 11 2 4 Dimensions fo...

Page 10: ...TION Use an NQPACK128RD socket manufactured by Tokyo Eletech Corporation for the FP 128 package IC socket on the user system Figure 1 shows the configuration of the HS2633ECH61H user system interface...

Page 11: ...2 Figure 1 HS2633ECH61H User System Interface Cable...

Page 12: ...dy 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 128 package 4 Socket cover 1 For installing an FP 128 packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For insta...

Page 13: ...make sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructi...

Page 14: ...5 Figure 2 Connecting User System Interface Cable to Emulator Station...

Page 15: ...HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions bel...

Page 16: ...r slops gently over the leads and forms solder fillets Use slightly more solder than the MCU 2 2 3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting Align pin 1 on the IC socke...

Page 17: ...sed by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fas...

Page 18: ...9 Figure 4 Connecting User System Interface Cable to User System...

Page 19: ...10 2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body...

Page 20: ...m with an IC socket for an FP 128 package NQPACK128RD manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad Un...

Page 21: ...12 2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Figure 7 Dimensions for User System Interface Cable Head...

Page 22: ...Connecting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 8 Figure 8 Resulting Dimensions after Conne...

Page 23: ...screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction wi...

Page 24: ...15 User system Screws M2 x 6 mm IC socket Tokyo Eletech Corporation NQPACK128RD Socket cover MCU Pin 1 Figure 9 Installing MCU to User System...

Page 25: ...the clock in the emulator station as the system clock by using the CLOCK command emulator command To use the external clock on the user system Select external clock t or t2 with the CLOCK command emu...

Page 26: ...not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator st...

Page 27: ...nual Publication Date Rev 5 00 January 29 2004 Published by Sales Strategic Planning Div Renesas Technology Corp Edited by Technical Documentation Information Department Renesas Kodaira Semiconductor...

Page 28: ...H8S 2633 Group QFP 128 User System Interface Cable HS2633ECH61H User s Manual REJ10B0085 0500H...

Reviews: