background image

Section 5   Notice 

1.  Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable 

head before inserting the cable head into the user system IC socket. 

2.  The dimensions of the recommended mount pad for the user system IC socket are different from 

those of the MCU.   

3.  This user system interface cable is specifically designed for the HS3L08EPI60H emulator.  Do 

not use this cable with any other emulator station.   

4.  To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the 

user system interface cable. 

5.  While the emulator station is connected to the user system with the user system interface cable, 

force must not be applied to the cable head.  Place the emulator station, user system interface 
cable, and user system as shown in the example in figure 10. 

 

Figure 10   User System Interface Cable Location Example 

17 

 

Summary of Contents for FP-80B

Page 1: ...H8 3637 Series FP 80B User System Interface Cable HS3637ECF61H for E6000 Emulator User s Manual ADE xxx xxx Rev 4 0 4 1 03 Renesas Technology Corp HS3637ECF61HE...

Page 2: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 3: ...the Renesas s original microcomputer H8 3637 series The HS3637ECF61H is a user system interface cable that connects an H8 3637series E6000 emulator HS3L08EPI60H hereinafter referred to as the emulator...

Page 4: ...IC Socket 6 2 2 2 Soldering IC Socket 6 2 2 3 Inserting Cable Head 7 2 2 4 Fastening Cable Head 7 2 2 5 Fastening Cable Body 9 2 3 Recommended Dimensions for User System Mount Pad 10 2 4 Dimensions fo...

Page 5: ...N Use an IC149 080 012 B5 socket manufactured by YAMAICHI ELECTRONICS Co Ltd for the FP 80B package IC socket on the user system Figure 1 shows the configuration of the HS3637ECF61H user system interf...

Page 6: ...IC socket Cable head Screws M2 x 12 mm with flat washers for fastening cable head Screws M2 x 8 mm with flat washers Socket cover To emulator station Cable body Figure 1 HS3637ECF61H User System Inter...

Page 7: ...tity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 80B package 4 Socket cover 1 For installing an FP 80B packaged MCU 5 Screws M2 x 12 mm 4 For fastening cable head with fo...

Page 8: ...ke sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instruction...

Page 9: ...Figure 2 Connecting User System Interface Cable to Emulator Station 5...

Page 10: ...ult in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket After checking the location of pin 1 on the I...

Page 11: ...rewdriver whose head matches the screw head 2 The tightening torque must be 0 0785 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the s...

Page 12: ...Each screw should be tightened a little at a time alternating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC sock...

Page 13: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 9...

Page 14: ...et for an FP 80B package IC149 080 012 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd Note that the dimensions in figure 5 are somewhat different from those of the actual chip s mount pad 10 Unit mm 0...

Page 15: ...2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6 Figure 6 Dimensions for User System Interface Cable Head 11...

Page 16: ...necting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 7 Figure 7 Resulting Dimensions after Connecti...

Page 17: ...ew head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with...

Page 18: ...MCU Pin 1 IC socket IC149 080 012 B5 manufactured by YAMAICHI ELECTRONICS Co Ltd User system Screws M2 x 8 mm with flat washers Socket cover Figure 8 Installing MCU to User System 14...

Page 19: ...he external clock on the user system as the system clock Select target clock t2 with the CLOCK command emulator command Supply the external clock from the user system to the emulator When a crystal os...

Page 20: ...input specifications 16 R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator 0 8 Vcc 55 ns max 55 ns max 0 8 Vcc 0 3 Vcc 0 V Vcc Vcc User System Vcc 3 0 V to 5 0 V 0 3 Vcc Su...

Page 21: ...ifically designed for the HS3L08EPI60H emulator Do not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the...

Page 22: ...6 The P1 short connector is used for testing Do not remove the inserted jumper pin P1 3 1 Figure 11 P1 Short Connector 18...