Summary of Contents for FP-128

Page 1: ...ok over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electron...

Page 2: ...t for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas...

Page 3: ...H8S 2636 Series FP 128 User System Interface Cable HS2636ECH61H for E6000 Emulator User s Manual User s Manual...

Page 4: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Page 5: ...sas s original microcomputer H8S 2636 series The HS2636ECH61H is a user system interface cable that connects an H8S 2636 and H8S 2646 series E6000 emulator HS2646EPI61H hereinafter referred to as the...

Page 6: ...C Socket 6 2 2 2 Soldering IC Socket 7 2 2 3 Inserting Cable Head 7 2 2 4 Fastening Cable Head 8 2 2 5 Fastening Cable Body 10 2 3 Recommended Dimensions for User System Mount Pad 11 2 4 Dimensions fo...

Page 7: ...TION Use an NQPACK128RD socket manufactured by Tokyo Eletech Corporation for the FP 128 package IC socket on the user system Figure 1 shows the configuration of the HS2636ECH61H user system interface...

Page 8: ...Figure 1 HS2636ECH61H User System Interface Cable 2...

Page 9: ...dy 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 128 package 4 Socket cover 1 For installing anFP 128 packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For instal...

Page 10: ...ke sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instruction...

Page 11: ...Figure 2 Connecting User System Interface Cable to Emulator Station 5...

Page 12: ...ZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below...

Page 13: ...to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU 2 2 3 Inserting Cable Head CAUTION Check the location of pi...

Page 14: ...sed by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Fas...

Page 15: ...Figure 4 Connecting User System Interface Cable to User System 9...

Page 16: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 10...

Page 17: ...ith an IC socket for an FP 128 package NQPACK128RD manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad 11 Un...

Page 18: ...2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Figure 7 Dimensions for User System Interface Cable Head 12...

Page 19: ...necting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 8 Figure 8 Resulting Dimensions after Connecti...

Page 20: ...screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction wi...

Page 21: ...Figure 9 Installing MCU to User System 15...

Page 22: ...he user system For details refer to the Emulator Supplementory Information HS2646EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock by using the CL...

Page 23: ...ifically designed for the HS2646EPI61H emulator Do not use this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the...

Page 24: ...6 The P1 jumper socket is used for testing Do not remove the inserted jumper pin P1 3 2 1 Figure 12 P1 Jumper Socket 18...