![Renesas Emulation Pod for M30240 Group MCUs M30240T-RPD-E User Manual Download Page 31](http://html1.mh-extra.com/html/renesas/emulation-pod-for-m30240-group-mcus-m30240t-rpd-e/emulation-pod-for-m30240-group-mcus-m30240t-rpd-e_user-manual_1440929031.webp)
( 29 / 58 )
3.4 A-D Conversion Bypass Capacitor
This product has foot patterns on the board for mounting a bypass capacitor. Mount a suitable bypass
capacitor as occasion demands.
Figure 3.8 shows where the bypass capacitors are mounted and an enlargement of the foot patterns.
Figure 3.8 Foot patterns of A-D conversion bypass capacitor
IMPORTANT
Notes on A-D Converter:
• Because a flexible cable and other devices are used between the emulator MCU and
the target system, the A-D converter operates differently from the actual MCU.
Make the final evaluation of the A-D converter from the actual MCU.