background image

1. Description

This accessory tool connects an emulation pod and the target. It can be mounted on the same 
foot pattern as the MCU housed in the 80-pin 0.65mm

 

pitch QFP.

 It is applicable to the M16C and 740 Family, etc.

2. Package Components

 (see Figure 1)

(1) DIRECT80S main unit (16.8x16.8mm)

(2) DIRECT80S User's Manual (this manual)

Figure 1  Package components of M3T-DIRECT80S

M3T-DIRECT80S main unit

(2/4)

4. Application

 (see Figure 2)

Mount this dummy IC on the foot pattern on the target. 
Then connect the emulation pod at the top of dummy IC.

Figure 2  Usage of M3T-DIRECT80S

M3T-DIRECT80S

Emulator

3. Specifications

Table 1  Specifications

5. Target Foot Pattern

Figure 3 shows the recommended foot pattern of M3T-DIRECT80S.

Before using M3T-DIRECT80S, be sure to read the 
precautions on page 3.

     : position of No 1 pin
Be sure to match the position of 
No. 1 pin of the foot pattern and 
each part.

Figure 3  Recommended foot pattern of M3T-DIRECT80S

12.35

0.65±0.05

0.35±0.05

14.6

Min. 17.5

12

.3

5

0.6

5

0

.35

1

4.6

Min

. 1

7.5

Note: The recommended foot pattern of M3T-DIRECT80S is a common foot pattern for 80P6
S-A and M3T-DIRECT80S. For DUMMY80S, use the foot pattern recommended by 
Matsushita Electric Works, Ltd. shown in the DUMMY80S User's Manual.

Item

Max. current

Insulation resistance

200mA, 5V

100M

 or over

(80-pin 0.65mm-pitch QFP)

Description

Package

Insertion/removal 

iterations of connector

20 times guaranteed

PRQP0080JA-A (formerly: 80P6S-A)

Reviews: