5. Connection Procedure 

(See Figure 3)

The procedure for connecting the M3T-F160-128NRD is
shown below.

(1) Mount the NQPACK128RD on the target system.

(2) Attach the YQPACK128RD on the NQPACK128RD.

(3) Secure the four corners of the YQPACK128RD with the

YQ-GUIDE's.

• Do NOT use the screws included with the

YQPACK128RD.

• Do NOT use the screwdriver included with the

NQPACK128RD that is used only for the
HQPACK128RD.

(4) Attach the probe of the emulation pod to the M3T-F160-

128NRD.

(5) Attach the M3T-F160-128NRD on the YQPACK128RD.

Figure 3 Connection procedure

6. External Dimensions and a Sample Foot Pattern

Figure 4 External dimensions and a sample foot pattern

Unit: mm

M3T-F160-128NRD

YQ-GUIDE's (x4)

YQPACK128RD

NQPACK128RD

128-pin 0.5-mm-pitch

(128P6Q-A) foot pattern

FLX160-PRB

or

M3xxxxTx-EPB

Use a slotted screwdriver.

: Position of No. 1 pin

Be sure to align the pins.