Items
Specifications
Clock selection
•
Software selection of 2 types of clocks:
•
User system clock (via user cable)
•
Emulator internal clock 2
−
16 MHz at 100KHz
resolution
Execution time
measurement
•
Measure the start (run) till end (break) of an execution.
•
Resolution: 50ns
•
No upper limit
User Cable interface
•
Two fine-pitch user cable assemblies (KEL-8822E-080-
171-040-AC) are used to interface to two 1.27mm pitch
plug (KEL-8830E-080-170S) on both sides of the
emulator and user target. (Provided in package)
•
Selected actual footprint user cables for each
microcomputer series are also available. (Not in
package)
Voltage Follower
•
Automatic tracking of the target system supply voltage
to ensure that the emulator draws no power.
Power Supply
•
Power Adaptor Input: 100-240 Vac, 50-60 Hz
•
Emulator Voltage : 5V Regulated
•
Current consumption : 2.6A (max)
Environmental
•
Operating Temperature : 10ºC to 35ºC
•
Humidity : 30% to 85% RH
•
No condensation
•
No corrosive gas
Field Upgrade
•
Re-programming of emulator logic and flash OS via
USB interface.
6
www.DataSheet4U.com
Summary of Contents for CE2000-H8S Series
Page 2: ...Blank Page www DataSheet4U com...
Page 22: ...Blank Page 8 www DataSheet4U com...
Page 41: ...Blank Page 27 www DataSheet4U com...
Page 57: ...Figure 6 1 Basic Bus Cycle Timing in Expanded mode 43 www DataSheet4U com...
Page 59: ...Blank Page 45 www DataSheet4U com...
Page 84: ...70 Blank Page www DataSheet4U com...
Page 88: ...Part Number 8830E 080 170S Unit mm inch B 2 www DataSheet4U com...
Page 95: ...Renesas Technology Asia Sales Offices URL http www renesas com G 1 www DataSheet4U com...
Page 96: ...CE2000 www DataSheet4U com...