Renco PREG-ALERT PRO Instruction Manual Download Page 4

PREG

ALERT

 

PRO

®

 

INSTRUCTION

 

MANUAL

  

Rev.

 

2

     

7/1/2007

 

The

 

probe

 

must

 

make

 

good

 

contact

 

with

 

the

 

skin

—air

 

bubbles

 

will

 

block

 

ultrasound.

  

A

 

coupling

 

fluid

 

such

 

as

 

cooking

 

oil,

 

must

 

be

 

used

 

to

 

enable

 

good

 

contact.

  

Apply

 

the

 

coupling

 

fluid

 

liberally

 

to

 

the

 

skin,

 

probe

 

or

 

both.

  

Press

 

the

 

probe

 

to

 

the

 

skin,

 

using

 

a

 

rotating

rocking

 

motion,

 

such

 

that

 

all

 

air

 

bubbles

 

are

 

removed.

 

 

The

 

number

 

one

 

problem

 

in

 

using

 

ultrasound

 

instruments

 

is

 

lack

 

of

 

good

 

skin

 

contact.

  

We

 

repeat,

  

Ultrasound

 

will

 

not

 

pass

 

through

 

air

 

bubbles!

   

 

USING

 

THE

 

PREG

ALERT

 

PRO

 

In

 

order

 

to

 

use

 

the

 

instrument

 

efficiently

 

and

 

with

 

the

 

best

 

results,

 

it

 

must

 

be

 

understood

 

that

 

this

 

instrument

 

is

 

a

 

tool

 

and

 

like

 

most

 

tools,

 

skill

 

is

 

best

 

obtained

 

by

 

intelligent

 

practice.

  

The

 

instrument

 

helps

 

you

 

by

 

providing

 

a

 

computer

 

enhanced

 

display

 

where

 

spurious

 

information

 

is

 

largely

 

eliminated,

 

but

 

the

 

user

 

must

 

be

 

the

 

one

 

to

 

decide

 

the

 

true

 

meaning

 

of

 

the

 

displayed

 

information.

  

 

Backfat

 

and

 

loin

 

measurement

 

are

 

easier

 

to

 

learn

 

than

 

pregnancy.

  

As

 

regards

 

pregnancy

 

detection,

 

both

 

the

 

animal

 

type

 

and

 

days

 

after

 

conception

 

at

 

which

 

testing

 

is

 

done

 

are

 

determining

 

factor

 

related

 

to

 

ease

 

of

 

use

 

and

 

skill

 

requirement.

  

To

 

illustrate,

 

on

 

the

 

one

 

hand,

 

swine

 

at

 

30

 

days

 

are

 

perhaps

 

the

 

easiest,

 

while

 

on

 

the

 

other

 

hand,

 

cattle

 

at

 

very

 

early

 

times

 

are

 

more

 

difficult.

 

 

Fat

 

measurement:

  

Select

 

the

 

FAT

 

screen.

  

Most

 

backfat

 

testing

 

in

 

swine

 

for

 

example

 

is

 

done

 

over

 

the

 

last

 

rib

 

and

 

40

60mm

 

off

 

the

 

center

 

line

 

(called

 

the

 

“P2”

 

test

 

site).

  

This

 

test

 

site

 

is

 

also

 

important

 

for

 

making

 

the

 

standard

 

loin

 

measurement.

  

Sometimes,

 

measurements

 

at

 

multiple

 

sites

 

in

 

this

 

region

 

are

 

used.

 

 

Loin

 

muscle

 

measurements

 

include

 

skin

 

and

 

backfat,

 

so

 

to

 

measure

 

just

 

the

 

loin

 

thickness,

 

first

 

determine

 

backfat

 

thickness,

 

using

 

the

 

backfat

 

screen

 

and

 

then

 

measure

 

the

 

loin

 

and

 

subtract

 

the

 

backfat

 

reading.

  

Of

 

the

 

two

 

LOIN

 

screens,

 

select

 

the

 

one

 

with

 

the

 

range

 

appropriate

 

for

 

the

 

total

 

thickness

 

involved.

  

Internal

 

adjustments

 

are

 

made

 

to

 

the

 

speed

 

of

 

sound

 

factor

 

to

 

minimize

 

the

 

effect

 

of

 

the

 

difference

 

between

 

fat

 

and

 

muscle

 

tissue.

 

 

Pregnancy

 

indications:

 

Each

 

Pregnancy

 

screen

 

except

 

the

 

OTHER

 

screen,

 

has

 

a

 

black

 

bar

 

at

 

the

 

bottom.

  

The

 

bar

 

indicates

 

the

 

proximate

 

distance

 

to

 

the

 

near

 

and

 

far

 

points

 

of

 

the

 

uterus

 

at

 

the

 

number

 

of

 

days

 

indicated.

  

It

 

is

 

important

 

to

 

understand

 

that

 

although

 

the

 

pregnancy

 

screens

 

named

 

Pig,

 

Sheep

 

and

 

Cow

 

have

 

been

 

tailored

 

for

 

the

 

specific

 

animal,

 

the

 

screen

 

can

 

be

 

used

 

for

 

any

 

animal

 

with

 

the

 

proximate

 

body

 

dimensions

 

of

 

the

 

named

 

animal.

  

A

 

fourth

 

pregnancy

 

screen,

 

called

  

OTHER

,

 

can

 

be

 

used

 

for

 

all

 

small

 

and

 

medium

 

mammals,

 

but

 

not

 

for

 

large

 

mammals.

  

In

 

addition

 

when

 

testing

 

large

 

mammals

 

at

 

very

 

early

 

times,

 

e.g.

 

cows,

 

mares,

 

bison,

 

etc.,

 

the

 

optional

 

Deep

 

probe

 

should

 

be

 

used.

 

 

©2007

 

Renco

 

Corporation

  

 

Page

 

4

 

of

 

13

 

 

 

한국대리점: 길우트레이딩 02)2636-0009 팩스02)2636-4753   서울시 영등포구 양평동 3가 40-2 에이스테크노타워703호    [email protected]    www.gilwoo.co.kr

Summary of Contents for PREG-ALERT PRO

Page 1: ...PREG ALERT PRO INSTRUCTIONS Rev 2 02 2636 0009 02 2636 4753 3 40 2 703 giltron chol com www gilwoo co kr...

Page 2: ...d marker on each screen Adjust to depth of interest using right and left arrow keys This marker is calibrated and the distance is displayed on the right side of the screen In these Instructions scales...

Page 3: ...that were generated by the ultrasonic pulses emitted by the transducer also called the probe Sound travels at different speeds through fat and muscle The instrument uses the appropriate speed for eac...

Page 4: ...ment Select the FAT screen Most backfat testing in swine for example is done over the last rib and 40 60mm off the center line called the P2 test site This test site is also important for making the s...

Page 5: ...use the important thing to look for is a strong high spike or group of spikes in the area of interest as displayed on the screen Pregnancy can be determined either by sensing the fetus or the interfa...

Page 6: ...g to identify very early pregnancy then since the reading is at the left end of the black bar it would probably be indicating a thickened uterine wall The Deep probe would be used for this In actual u...

Page 7: ...nd mares testing should be started on the left side If no pregnancy is detected then try the other side in all cases but be cautious of the results in ruminate animals where the rumen might interfere...

Page 8: ...ting swine on right side and if not pregnant try again on the left side Testing can begin at 18 days testing every day until positive readings are obtained 2 days in a row Accuracy is greatest at 30 d...

Page 9: ...35 days Test on left side if not successful It may be necessary to remove wool and dirt from test site Pregnancy Test Site for Alpacas Begin testing alpacas on the LEFT side at about 45 days Test on...

Page 10: ...iangular region forward of the hook bone just behind the ribs and about 8 inches 20cm down from the backbone Locate the lowest spot in the fossa into which the probe will fit comfortably by pressing i...

Page 11: ...MANUAL Rev 2 7 1 2007 Pregnancy Test Site Mares Side View Pregnancy Test Site for Mares Left Side View Right Back View 2007 Renco Corporation Page 11 of 13 02 2636 0009 02 2636 4753 3 40 2 703 giltron...

Page 12: ...ation progresses you should move the probe downwards within the area shown by the outline in the side view Side View Position 2 is for use after approximately 90 100 days and the Standard probe may be...

Page 13: ...x 612 333 9026 Email TechSupport Rencocorp com Internet http www rencocorp com CAUTION DO NOT USE THE PREG ALERT PRO ON HUMAN BEINGS CERTIFICATION AND COMPLIANCE FCC Required 15 21 Information to User...

Reviews: